HVAC, Plumbing, & Electrical Services
Simple Answer: We always answer the phone, and come when you call to fix what needs fixed — and we stand behind our word and our work.
Plus you can count on getting a Certified AC Genius, Plumbing Genius, or Electrical Genius. Which means we don’t use “salesmen in disguise” or “selling techs,” like other home service companies. Instead we have our own training center to ensure you always get the honest expertise required to repair your problem right, right then and there.
Comfort Experts is proud to serve Hudson Oaks, TX, and the surrounding areas with quality, comprehensive HVAC services. Since 1962, we’ve helped local homeowners take their indoor comfort to the next level. Whether you need installation, replacement, maintenance or repair, we’ve got you covered – 24/7! We offer a wide range of services, including AC, heating, plumbing, electrical and solar energy. We’re proud to offer a free second opinion so you know you’re always getting a fair deal. With Comfort Experts, you’ll never have to compromise on comfort. We know the ins and outs of heating, cooling and more so you don’t have to.
See what your Hudson Oaks, TX, neighbors are saying about our exceptional service. We’re here for you day and night, so when you need HVAC care you can trust, give us a call at (817) 341-5149!
Mark was understanding about my situation and had the soft start system installed at no cost. Nate installed it and it appeared to work perfectly. He will return to finish it out. Hopefully the soft start system remedies the compressor issues with my Amana A/C Heat Pump system.
Mark is hands down the best technician we have ever worked with.
Hunter was knowledgeable, thorough, and gave us all the pertinent information to questions we asked. The service was excellent!
Hunter was very Courteous and Knowledgeable
Alex was our HVAC installation Tech. Alex was very good and did a great job. Very satisfied.
Cody was knowledgeable and professional. He was able to quickly service my unit and replace the UV bulb.
Ian was able to quickly find the problem and get the compressor working again.
I would definitely recommend them! Quick and friendly service. I called them about 7:30 pm Sunday and they were here the very next day Monday @ 10 am to fix my AC. Ian Conrad is definitely great at his job, and very professional. Thank you to hum, and their company. If I could I would give them 10 stars
Mark is excellent and thorough!
Cody was efficient and pleasant and Explained everything he did and everything he found …. Enjoyable
Ian was very professional and explained everything as he went. He diagnosed and cleaned my unit without Hard selling me on anything new. I really appreciate his honesty and work ethic.
Good explanations using visuals, pleasant , good demeanor – pleasure to have in my home
Ian was very courteous and worked hard to complete our work and ensure it was running as it should before he left thank you to him and all of the Hobson staff for taking care of us and our air conditioning needs!! Highly recommend them
Mark’s attention to detail and thorough explanations provided peace of mind.
Tyler was professional, honest & respectful. Appreciate Corin promptly correcting the scheduling mistake the original service scheduler made with my appt..
Tyler is beey knowledgable
Appreciate Justin being on time, courteous & knowledgeable! He was efficient & informative. Plan to reschedule him for installation of a compressor saver, appreciate not being pressured to make that decision today, I would NOT have considered or trusted his suggestion had I been pressured!
Mark was very efficient ,pollite and knowledgeable
Great technician
Very thorough! Took his time and reviewed everything with me at the end. Very professional.
Dennis was very courteous & professional in our scheduled fall time tune-up. Thank you and Dennis too. The Solt family
Justin was knowledgeable and did his work quickly.
Cole kept in touch with us about his arrival time and was able to quickly diagnose and repair the problem!
Scheduled to return on Tuesday the 4th, I identified that the 3-ton system's single 14" return duct and 20×12 return grill were insufficient, providing only half the required return air. To rectify this, I installed a second return grill and duct, and upgraded the return plenum to accommodate both ducts. The TXV was not replaced, and the previously paid warranty refrigerant charge was applied to this job.
I was scheduled to perform a comprehensive inspection and maintenance of the HVAC system, including checking the air filters, cleaning the coils, and ensuring all components were functioning properly. Upon arrival, I was informed that the customer had cancelled the appointment. Despite the cancellation, I ensured that all equipment was left in good condition and provided the customer with a detailed report of the inspection.
Upon inspection, the compressor capacitor was found to have failed. I discussed the repair options with the customer, who agreed to proceed. After replacing the faulty capacitor, I checked the refrigerant levels to ensure optimal performance. We also explored the benefits of installing a soft start kit to enhance system efficiency. The system was left operational and cooling effectively.
Upon arrival, I identified a lack of low voltage power to the thermostat, which was caused by a popped 3 amp fuse. I replaced the fuse and meticulously inspected the wiring, ensuring all connections were secure and properly insulated. Additionally, I discovered a blockage in the primary drain, which I cleared to restore proper drainage. Following these repairs, I conducted a thorough function check to confirm the system was operational. The system was successfully running and cooling as expected when I left the site.
Kviviv
I had a conversation with Mrs. Yorek to discuss the warranty status of her current system and the options available for repairing or replacing it. She mentioned that she is currently occupied and unable to meet with a comfort advisor tomorrow. Mrs. Yorek assured me that she would review her schedule and contact the office to arrange a new appointment. I patiently explained the process and provided her with all necessary information to facilitate the scheduling of her meeting. I ensured that she understood the options available to her and the steps required to move forward with the replacement of her system.
Upon arrival, the system was unable to maintain the desired temperature of 70 degrees. The customer reported ongoing issues with the system's performance. Upon inspection, I discovered a blockage in the primary drain, which was causing the drain switch to trip. I cleared the blockage and conducted a function check to ensure the system was operating correctly. Further examination revealed that the compressor was excessively noisy and exhibited low differential pressure between the low and high side pressures. Additionally, the compressor's amperage draw was low while running, indicating internal failure. I informed the customer that the compressor needs to be replaced. A Comfort Advisor is scheduled to meet with the customer on Thursday morning to discuss the next steps.
Today, I successfully installed a new compressor and a thermostatic expansion valve (TXV). Due to adverse weather conditions and fluctuating temperatures, I charged the unit to the best of my ability. Recognizing the need for precise calibration, I contacted the office to schedule a follow-up visit. This will ensure that the charge is accurate and the system operates efficiently. My focus remains on delivering high-quality service and ensuring customer satisfaction.
We addressed the issue with the fill valve in the toilet, which was experiencing frequent malfunctions due to the hard water conditions in the home. Given the absence of a water softener, the fill valve was subjected to accelerated wear and tear. We replaced the existing fill valve with a new one designed to better handle hard water, ensuring improved performance and longevity. This proactive measure was taken to prevent future disruptions and maintain the efficiency of the toilet system. We also assessed the overall condition of the toilet and provided recommendations for additional maintenance to mitigate the effects of hard water.
The customer requested an estimate for replacing two 3-ton heat pumps. The bedroom unit's compressor was tripping the breaker. I conducted a function check, revealing the unit would run briefly before stopping. Using a megohm meter, I tested the windings and found all three damaged, causing the compressor to overheat. The customer opted to replace both systems. I provided a detailed assessment and estimate for the replacement.
I conducted a comprehensive system tune-up on three units, ensuring all electrical connections were secure and functioning properly. The air handler coils and blower motors were inspected and found to be in acceptable condition. However, slight biological growth was detected on the evaporator condensate pans. I also checked and tightened all electrical connections on the heat pumps, ensuring the dual run capacitors were within the acceptable range. Refrigerant levels were verified to be within the proper range. All primary electrical units were found to be acceptable. I cleared debris from the bottom of the units and thoroughly cleaned the coils from the inside out. Additionally, I recommended installing drain safety on the primary drain line and using UV systems to combat biological growth, along with compressor savers for added protection.
Upon arrival customer stated system will not run they're an evaluation found the system was out on hot head pressure most likely due to running heat previous days and also having extremely clogged filters change customers filters reset system check pressures and left the system in cool
Cooling tune up performed today on a 9 year old Coleman heat pump. All electrical connections are tight with no corrosion. Refrigerant levels are in range. All amp draws are within tolerance. Blower wheel and evaporator coil are clean. Outdoor unit was washed and waxed. UV bulb was replaced on this visit. System running and cooling the home upon departure.
Fun arrival customer stated system would not cool and has not cooled since winter during evaluation found the outdoor heat pump to be locked out on high pressure code reset system check pressures and cool outdoor temperature is mid 60s so wasn't able to get an accurate reading on refrigerant levels we're in the system in heat and check pressures along with air flow refrigerant levels in heat with slowly rise up and airflow was showing to be within range did find filters to be dirty recommended changing filters and if system were to lock out again give us a call Talked with customer about main kitchen sink not working customer like a plumber set up for next Friday 4/3/27 after 12:00 confirmed by the office
2024 Revolv Airhandler Checked and tightened all electrical connections Changed customer provided filters Drain was clear and draining at this time Blower Motor and wheel were acceptable Evaporator coil has slight dust and dirt build up 2024 Ducane Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Compressor LRA is over manufactured rating Refrigerant levels were acceptable Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Recommended HBPPLAN, Micro Air Soft Start Kit or compressor saver
Will return to install soft start kit
Perform super tune-up on outside unit and inside unit. Outside unit pulling proper amperage on all electrical components all electrical components are tight, all electrical components are pulling proper amperage, outside unit clean. Inside unit pulling proper amperage on all electrical components, he sensor and pressure switch are working, blower motor is clean and acceptable, customer changes out filter, upon departure unit is properly functioning.
Arrived to no heat. Found that the system had no refrigerant in it. Put nitrogen in the system and found an audible leak in the condenser before the reversing valve. Gave estimate for repair. Customer is interested in replacing the system. Comfort advisor is scheduled to meet with the customer this evening.
2016 Amana Airhandler Checked and tightened all electrical connections Filter was acceptable Heat strips were functional and within manufacture range Replaced customer provided UV lamp Drain was clear and draining at this time Blower motor and wheel were acceptable Evaporator coil was acceptable Zone board and system is functional 2016 Amana Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Compressor saver is functional Fan blades and motor were acceptable Condenser coils were acceptable Washed condenser coils from the inside out Recommended UV system upgrade, not interested in UV upgrade at this time
Completed STU. Found dual run cap out of tolerance and minor biological growth in indoor cabinet. Recommend adding safety to primary drain line, house panel surge protection and compressor saver
Completed STU. Found dual run cap out of tolerance and minor biological growth in indoor cabinet. Recommend adding safety to primary drain line, house panel surge protection and compressor saver
Completed STU. Found dual run cap out of tolerance and minor biological growth in indoor cabinet. Recommend adding safety to primary drain line, house panel surge protection and compressor saver
Completed STU. Found dual run cap out of tolerance and minor biological growth in indoor cabinet. Recommend adding safety to primary drain line, house panel surge protection and compressor saver
No answer at the door. Pausing for now Performed Tune upon system Found Airhandler to be extremely compacted with dust and dirt due to the homeowner tearing down walls and flooring in the house. Customer also wanted to know if we could lift unit or move unit to replace flooring under Airhandler, gave customer a price and they declined. AIRHANDLER DOES NOT HAVE ENOUGH RETURN AIR AIRHANDLER HAS THE WRONG FILTER IN FILTER BOX AND HAD THE FILTER DOOR OFF LETTING UNFILTERED AIR BYPASS THE FILTER. COMPRESSOR IS NOT RUNNING EFFICIENTLY AND DOES NOT SOUND GREAT. DUE TO THE COIL BEING HEAVILY COMPACTED AND ALMOST NO RETURN AIR THE REFRIGERANT LEVELS ARE SHOWING LOW AND LINESET IS FREEZING. COMPRESSOR MAY FAIL SOON RECOMMENDED NOT RUNNING THE SYSTEM TILL THE AIRHANDLER IS CLEANED AND ALL WORK IS DONE ON THE HOUSE Payment was being processed by the time tech left and said it failed so will be pausing for now.
I have replaced the 30 amp double pole breaker for the dryer