Trophy Club AC & Heating Services
The purpose of your heating, air conditioning and ventilation system is to provide a comfortable and safe environment inside your home. This could be anything from keeping your home heated or cooled at your preferred temperature to improving the indoor air quality and circulation of your home to help fight against respiratory and other illnesses. Can you guarantee that your unit is running at its full potential and successfully providing the ideal comfort and safety for your Trophy Club home? If you answer “no” to this question it is time to have your unit inspected. Call us today at 817-341-5149 to schedule your inspection!
Trophy Club AC Repair & Replacement
If your unit is unable to be repaired and has to be replaced, we’re here to quickly get a new unit put in so you can get back to the comfort you deserve. All you have to do is choose a new system! We provide a wide range of HVAC units to choose from so we know that you will be able to find a new system that caters to your needs.
Our 5-star online reviews show that we are dedicated to customer satisfaction. We have made it our goal to leave you saying that you had a good experience with our company. We take pride in the work we do and always back our work with a 100% customer satisfaction guarantee. You will always be left satisfied and we will always leave knowing we have successfully assisted your family with your Trophy Club AC repair needs.
Here For All Your HVAC Needs
Comfort Experts, Inc. has made it our mission to keep Trophy Club families comfortable all year long and assure that your home is a safe environment. No matter the issue with your heating and cooling systems, we’re here to help. By offering AC inspection and repair, we can diagnose a malfunction quickly and fix the problem, returning your system to peak performance.
In addition to heating and cooling, we specialize in plumbing and electrical services so you don’t have to worry about hunting down multiple contractors. We take care of all your HVAC systems from start to finish. For the most comfortable call you’ll ever make, we’ll be here 24/7 at 817-341-5149 !
Local Reviews
for Trophy Club, TX
Our Reviews by City
Excellent Service
Bettye - Trophy Club, TX 76262
Zac did a great job.
Consistent Excellence
John - Trophy Club, TX 76262
Service
Jorge - Trophy Club, TX 76262
Great job
James - Trophy Club, TX 76262
Alex and his colleague stuck out the coldest day of the year. Every time I saw Alex he had a smile on his face and both were courteous and respectful the whole time they were freezing their you know what’s off. The new unit is working great! I appreciate the great work and great service.
Very Professional Service!
Anthony - Trophy Club, TX 76262
Great Service
Steven - Trophy Club, TX 76262
Joe and Jose with his team replaced 2 full systems for me. They did it to my 100% satisfaction with professionalism. This is by far the best contractor experience I have had. Before he left he tested everything with me to ensure I was satisfied. I would use comfort experts again for sure.
Highly competent service with a smile
Marjorie - Trophy Club, TX 76262
it was his last call of the day, it had begun to rain, and he had a long drive back home ahead of him. But he cheerfully checked out the system, indoors and out, found a drainage problem that required extra time to fix, eliminated the small gas leak that required service in the first place, and left me two furnaces perfectly tuned and running. Throughout all this he was cheerfully took all the time the work needed. I am grateful to Comfort Experts for hiring such fine people!l
Great
Marjorie - Trophy Club, TX 76262
It wasn't mark Bennett who was here; it was Ty, and you should be very pleased to have such an excellent young man on your staff. He is competent, informative, pleasant, and does excellent work. Thanks
Great service
Kathy - Trophy Club, TX 76262
Our technician came for our annual inspection. He was extremely polite and listened to every concern. Made sure to address all issues before leaving.
Jim
Mark - Trophy Club, TX 76262
The crew was friendly and efficient. I thought they did a wonderful job.
Technician was polite friendly and profession as our Technician
Pat - Trophy Club, TX 76262
Diego M.
Upon arrival system was in working condition. Looking at the indoor unit all electrical connections and components are good. Blower and coil are clean. Drain lines are clear. Filter was changed. Looking at the outdoor unit all electrical connections and components are good. Capacitor within tolerance. Refrigerant levels are good. Amp draws are good. Cleaned unit inside out. Left system in working condition. Thank you for choosing comfort experts.
Tyler L.
Completed electrical estimate they have signed for the current estimate but I will be calling tomorrow to get assurance that they want to proceed with the transaction
Ian C.
Capacitor failure. Swapped warranty capacitor Amp draws acceptable Coils clean Refrigerant levels acceptable Deltas acceptable
Zak L.
Arrived for service eval Error code for high pressure lockout Condenser coil very dirty and dusty Cleaned coil
colby.finch@acgenius.com
On arrival the outdoor unit was not running. I quickly determined that the drain line was clogged causing the unit to short cycle. After taking the p trap apart I blew and sucked from the top and bottom. I poured a gallon of water down the drain line to test and had no issues. I also installed Zac's uv200 while there. Thanks for choosing comfort experts and have a great day;
Aaron W.
Upstairs outdoor unit is operating refrigerant levels are slightly low, fan motor is amping slightly high ,downstairs outdoor unit is operating, refrigerant levels are low,cap is out of tolerance ,upstairs indoor unit is operating ,drain line is clear at thistime, filter is serverly dirty, customer needed size before replacing, downstairs indoor unit is operating, system is serverly dirty,drain line is clear at this time, cap for upstairs was replaced last year, need to follow up with customer in August about duct cleaning ,installed both caps, waiting for fan motor to come in ,left both system cooling
Jhorden P.
Install 48k gas hz system keep current filtration
colby.finch@acgenius.com
On arrival the outside unit was off and not turning on. The unit was getting a call for cooling from the thermostat, but had no high voltage. I found the main breaker and saw that the unit had tripped the breaker. I ohmed out the compressor wires and had measurable resistance, and I turned the unit on with the compressor unattached and the fan turned on and ran. With the compressor re attached it instantly tripped the breaker. With all of this information I was able to determine that the compressor is grounded. I set up a call with our comfort advisors to talk about options. Thanks for choosing comfort experts and have a great day!
Jeffrey B.
Arrived at location and spoke with home. Home owner indicated system not cooling properly. Inspected system. Capacitor blown. Recommended replacement. Home owner agreed. Replaced capacitor. System functioning and cooling properly upon departure.
Steven S.
Upon arrival for service system on and not cooling. Inspected system and found capacitor out. Replaced capacitor under warranty. Tested system. All amp draws voltages and refrigerant pressures good. Left system on and cooling. Customer states issue with thermostat connecting to wifi. Troubleshooted issue. Thermostat registered to another user on the app prevent customer from connecting to thermostat.
Alec G.
Upon arrival to customers house system was cooling Air handler Blower wheel clean EVAP coil clean Drain line clear Filter clean Electrical connections good Heat pump Fan motor good Compressor good Electrical connections good Cap within tolerance Contactor good Refrigerant levels good Disconnect working properly Leaving customers house system was cooling
Jeffrey B.
Arrived at location and spoke with home owner. Inspected indoor units. Both units electrical connections tight. Coils clean and in good condition. Temperature deltas within acceptable range. Blower wheels clean. Drains clear with safety switches in place. Lennox system blower capacitor out of spec. Recommended replacement. Inspected outdoor units. Both units electrical connections tight. Coils clean and in good condition. Fan and compressor Amp draws good. Refrigerant charges good. Both capacitors out of spec. Recommended replacement. Both compressors drawing excessive current on startup. Recommended compressor saver kit for both units.
Zak L.
Arrived for service eval Condenser error code locked rotor amps Dual run cap rated 30/5 testing at 15 Hard start kit blown Replaced both with membership warranty Refrigerant fine System running in cooling at exit
Mike S.
Arrived on site greeted cx thanked them for business. Moved to outdoor units tested all components all measured within ratings and specs. Refrigerant level is normal on all units. Washed and cleaned both units. Moved to indoor units tested all components safeties and switches all measured within ratings and specs. Blower wheels have slight build up recommend pull and clean. Coils and drains are clean and clear at this time. Offered UVC germicidal unit for both units, blower wheel pull and clean. Cx politely declined today scheduling follow up for May 10th.
javier.falcon@acgenius.com
Customer wanted me to run camera in main sewer line no clean outs so ran camera through toilet no issues found in pipe but was unsuccessful in putting the toilet back Flange needs to be replaced customer stated will wait until contractor remodels the restroom
Ryan S.
Performed ctu, system operation is normal, refrigerant levels in range, capacitor in tolerance, compressor pulling over lra, needs hard start to lower inrush amps, drains clear, changed filter, biological growth present inside supply plenum needs uv light to sterilize surface/ air. Cleaned fresh air intake screen.
Matt B.
Upon arrival found both systems heating and cooling with a 20 delta. Changed filters and inspected blower. Systems are a little dusty. Recommended UV systems for both systems. I will be following up with the customer regarding the air quality and UV purification in the house. Recommended compressor savers for outside unit and customer purchased compressor saver for the older of the two units. Checked capacitors on both systems and they were both perfect. Cleaned coils and waxed top ok condensers. Systems are cooling with a 20 delta
Steven S.
#iaq upon arrival for tune up on 3 year old Lenox gas furnace systems they were on and cooling. Ok Inspected outdoor units. Fan and compressor amp draw within unit specifications. Cleaned units. Capacitors out of tolerance. Refrigerant pressures good. Inspected indoor units. Blowers clean. Slight corrosion buildup on coils. Drain lines clear with pan safteys. Recommended replacement of capacitors. Customer agreed. Left systems on and cooling.
javier.falcon@acgenius.com
Issue with washer connection escalated and price went up customer needs approval from land lord before he pays for the service, as well as water heater pressure valve. Fridge line reconnected successfully.
Dennis C.
Downstairs: 10 year old Lennox gas system, primary electrical control, build up on blower wheel, duct cleaning. System is operating at this time. Upstairs: 10 year old Lennox gas system, dual run capacitor, primary electrical control, build up on blower wheel, duct cleaning. System is operating at this time.
Mike R.
4ton goodman heat output system stu tune up went vary smoothly I broke down the cage of condensor and gave it nice wash down cleaning I replaced the hard start existing caps and boards are in good conditions. The evap coil also vary clean along with the blower motor and the heat kit is fully functional. No solar at this time and water heater is good. Customer has taken all good measures to keep this system safe and healthy Thank-you for choosing comfort experts please call us if you have any further questions.
Ryan S.
Swapped boards system operation is normal
Ryan S.
Found furnace control board failed, when given a load to the transformer, voltage would drop. Customer purchased new board, customer presented coupon.
.
Install 12k heat pump mini split
Joel B.
Did a STU on 5year old Coleman system, checked capacitor found dual run capacitor weak, replaced under P&L WARRANTY, checked filter, flushed drain, checked flame sensor and ignitor, checked inducer motor, checked pressure switch, checked safety switches, recommended a compressor, refrigerant levels are good, customer verified unit was working properly when leaving C