Air Conditioning & Heating Services NearLipan, TX
Comfort Experts is proud to serve Lipan, TX, and the surrounding areas with quality, comprehensive HVAC services. Since 1962, we've helped local homeowners take their indoor comfort to the next level. Whether you need installation, replacement, maintenance or repair, we've got you covered - 24/7! We offer a wide range of services, including AC, heating, plumbing, electrical and solar energy. We're proud to offer a free second opinion so you know you're always getting a fair deal. With Comfort Experts, you'll never have to compromise on comfort. We know the ins and outs of heating, cooling and more so you don't have to.
See what your Lipan, TX, neighbors are saying about our exceptional service. We're here for you day and night, so when you need HVAC care you can trust, give us a call at 817-341-5149 !
Local Reviews
for Lipan, TX
Our Reviews by City
Excellent service
Carl - Lipan, TX 76462
Thank you feel better knowing that my propane heater is working correctly
LipanTX76462 32.4875-98.04



Good service
Tommy - Lipan, TX 76462
LipanTX76462 32.6075-97.915




Nice job
Dan - Lipan, TX 76462
Very helpful tech Zack found issues and addressed quickly and well.
LipanTX76462 32.61-97.92



Excellent!
Alyssa - Lipan, TX 76462
Alec was very knowledgeable, kind and thorough!
LipanTX76462 32.5325-98.05



Should have called here first!!
Kevin Hahn - Lipan, TX 76462
Justin was the absolute best! Courteous and knowledgeable and had to repair something another company got wrong! This will be my first and only call from now on.
LipanTX76462 32.61-97.935



Very good service
Sylvia - Lipan, TX 76462
Best service provider I’ve used. They returned my calls promptly and answered all questions. They scheduled my appointment according to my needs. Technician, Dennis, was on time and very nice. He answered all the f my questions and gave me options to consider. One of the best parts was he left everything clean and in place! He also secured my doors upon leaving. I was very pleased.
LipanTX76462 32.4825-97.92



On time and a great job
Howard - Lipan, TX 76462
Jeffery is my prefered tech.
LipanTX76462 32.5175-98.1025



Great servicec
Tommy - Lipan, TX 76462
Very professional and courteous
LipanTX76462 32.6075-97.915



Great and unexpectedly quick service on 22 December with a requested call after 2 o’clock in the afternoon and the technician showed up before 5 o’clo
Ben - Lipan, TX 76462
I think this HVAC company is top notch
LipanTX76462 32.6075-97.935



Very Happy
Stacy - Lipan, TX 76462
LipanTX76462 32.5175-98.045




Service call
Jim - Lipan, TX 76462
LipanTX76462 32.6075-97.9425




Great job.
Danny - Lipan, TX 76462
LipanTX76462 32.5875-97.9225




Very satisfied
Howard - Lipan, TX 76462
If you have to have a whole new system, a 3 day turn around is best.
LipanTX76462 32.5175-98.1025



Quick service
Anthony - Lipan, TX 76462
LipanTX76462 32.6125-97.9125




Good service
Tommy - Lipan, TX 76462
LipanTX76462 32.6075-97.915




Initial visit
Tommy - Lipan, TX 76462
Casey was great
LipanTX76462 32.6075-97.915



Unit is working again.
Jim - Lipan, TX 76462
I am happy that the unit is working.
LipanTX76462 32.6075-97.9425
Response from Comfort Experts Inc.:
Thank you Jim!




Great service; exceptionally nice young man
Bob - Lipan, TX 76462
Ryan explained the issue we were having and double checked what he needed to. He offered options for what we needed to do to make the repair and asked if there was anything else he could do for me at the end of the service call. Excellent service guy
LipanTX76462 32.6075-97.9375



Great service tech. Fair price.
Nick - Lipan, TX 76462
Tech super informed on all systems I had. Really nice guy.
LipanTX76462 32.6125-97.9125



Jordan is an employee to be treasured he was outstanding
Ben - Lipan, TX 76462
Jordan is an employee to be treasured he was outstanding
LipanTX76462 32.6075-97.935



Michael t. winfrey
Mark - Lipan, TX 76462
Great service
LipanTX76462 32.55-97.935




Ian C.
Propane heater is operating properly There was no water heater issue

Justin P.
2022 Amana Airhandler Checked and tightened all electrical connections Changed customer provided filter Drain is clear and draining poured a gallon of water down Blower motor and wheel were acceptable Evaporator coil was acceptable Heat strips were functional and within manufacture range Uv bulb is no longer working 2022 Amana Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacturers range Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable at this time Condenser coil was acceptable Fan blades and motor were acceptable Washed coil from inside out Waxed top of unit Replaced uv bulb and added compressor saver to system

Mike R.
I can out today because a low pressure switch has compressor off. I checked the rest of the system and found 3 very clogged filters 2 in the ceiling and 1 4 clogged 4 inch in the air handler. after changing filters I reset the system and gauged up to condenser to insure pressure was good. System is back online and cooling.

Dennis C.
1 year old Goodman heat: Compressor saver, uv system. System is operating normally at this time.

Brock S.
Ran AC tune up on system. Found capacitor to be weak, no surge protection on the house and compressor LRA to be at the limit of recommended amp draws. Also found indoor coil to be dirty, causing poor airflow and pressures to be off. Also found biological growth on inside of unit. Recommended to customer that due to the age of unit, and price of repairs, that a comfort advisor come out for a possible replacement. Found no other issues at this time. Wanted advisor out on 29th during the afternoon.

Mike R.
For this job I found the compressor plug blown out system needs a new one and hard start kit. The mini split to needed freon.

Alec G.
During inspection verified that system was working properly blower wheel clean EVAP coil clean Filter clean Drain line clear Electrical connections good Compressor good Condenser coil clean Fan motor good Refrigerant levels good Spoke with customer and let him know that everything was working properly and system should have a long life Left customers house with system cooling

Ryan S.
Upon arrival found condenser not running, found contactor had low resistance 1.3 ohms, replaced contactor and system operating normally.

tyler.scholes@acgenius.com
09/15/23 supposed leak under kitchen sink. I could not replicate the drip. All parts that I rebuilt are not leaking. Sent an estimate to replace the 45 bend near wall if they suspect a leak on that area. Trip charged

Mike S.
Customer has a bathroom in his son's room that is backed up clogging condensation drain line from indoor unit causing water to leak from a vent on the drain. I pulled the the line from the wall and water gushed out cleared ptrap and reassembled the used the faucet to test and sink is still backing up. Referring plumber dispatch advised they would reach out to customer in the morning with time frame of when we could have someone out.

Mark D.
On the previous visit, the technician believed the issue to be a bad breaker being that the condenser started and breaker stayed for the remainder of the visit. On this visit the breaker was not staying on and it was breaking almost immediately. Meg ohm checked the compressor to find that it has a short to ground. Technician believes that on previous visit the compressor may have had a floating ground that has now completely grounded. Need to order compressor under parts and labor warranty ASAP. System is down.

Mark D.
Arrived to no cool. 77 degrees inside the home. Outdoor unit was not turning on. Circuit board on the heat pump was giving 08 code meaning no line voltage. Discovered tripped 50 amp cutler hammer breaker. Flipped breaker and it tripped again. Meg ohm checked compressor to find it was fine. Flipped breaker back and it stayed. Technician believes the issue to be a bad breaker. Could not recreate the problem again. Customer states that #2 zone in the back bedroom doesn’t cool properly. Technician discovered that the dampener was not opening all the way. Opened the dampener all the way and performed function check 3 times to make sure dampener opened and closed as it should. Refrigerant levels are in spec and delta T is 19.5 degrees. Home was 77 degrees upon arrival and was 74 upon departure.

Zak L.
Arrived for service eval Drain line backed up on the first unit - cleared Filter very dusty and causing air flow issues in the farthest unit - cleaned filters Advised cleaning filters weekly while doing drywall/tile work inside the apartment Recommend extending drain lines to The bottom of the gutters covering the refrigerant lines to make clearing drain lines easier Recalling service fee due to dirty filters being missed at last visit

Dennis C.
3 year old Trane propane system: dirty condenser coil, dirty filter, dirty ducts. System is operating normally at this time. Cleaned condenser coil, replaced filter provided.

Mark D.
Customer wanted estimate for duct cleaning. Ducts looked clear however evap coil and blower wheel are very dirty. System is low on refrigerant however technician was unable to locate a leak. 40/5 dual run capacitor is weak and needs to be changed. Customer asked for estimates to be emailed to him so he can look everything over.

Mark D.
Technician discovered failed condenser fan motor. Changed out motor and capacitor. Performed function check. System running in cool upon departure.

Mike S.
On arrival found the system freezing over and low on charge , performed a leak search on system and found leak in the Evaporator coil. Ordered new coil utilizing PL warranty, per Mark W fill system up to get them by and will not charge freon fee as they just put freon in last week.

Diego M.
Upon arrival system was in working condition. Customer stated that system has not been cooling properly this week. Hooked up my gauges and system was low on refrigerant. Preformed a leak search. Found leaky at Schrader valve. Replaced shrader valve and topped unit off. Refrigerant levels are now acceptable. Left system in working condition. Thank you for choosing comfort experts.

Jeffrey B.
Arrived at location and spoke with home owner. Inspected system. System operating and cooling properly with 20 degree delta. Drain clear. Filter good. Refrigerant charge good. Blower wheel clean. Coil clean and in good condition. Outdoor coil clean.

Alec G.
Upon arrival to customers house system was cooling During my inspection I had discovered that the blower wheel and evaporator coil had biological growth on them and the ducts had some buildup inside of them Spoke with customer about a level 1 duct cleaning with a uv light installed for it to be cheaper then the level 2 duct cleaning but still be beneficial They said they needed to sleep on it and would call the office if they wanted to go any further with it Left customers house with system cooling

Kellen M.
Contacting Riley about the customer. We installed system from a closet to attic. Two Boots are condensating out of supply vents due to extreme lack of ventilation. Customer needs exhaust vents and insulation as there is none in the attic. Hvac to CA CALL ON 7/17/23 10am. Contacted Rob G for further instructions.

Mike S.
Arrived on site. customer said unit would turn on and off. Drain switch was tripped went to bathroom where drain was routed pulled off off p trap water came pouring out. Blew from top down line clear now system running.

Mike S.
Upon arrival sump pump clogged Emergency drain pan full of water Electrical safety issues assessed and fixed Compressor saver installed Will return 7/5/23

Mike S.
Arrived to eval System 1 Customer stated condenser would run and shut off Checked all electrical connections Found that the condenser fan motor run wire was connected to herm side of dual run cap Reconnected to c side of dual run cap System2 Is as it should be No problems found

Alex D.
Lv 3 42k gas horizontal, good leap 100%, install Saturday 6-24-23