HVAC, Plumbing, & Electrical Services
Simple Answer: We always answer the phone, and come when you call to fix what needs fixed — and we stand behind our word and our work.
Plus you can count on getting a Certified AC Genius, Plumbing Genius, or Electrical Genius. Which means we don’t use “salesmen in disguise” or “selling techs,” like other home service companies. Instead we have our own training center to ensure you always get the honest expertise required to repair your problem right, right then and there.
Comfort Experts is proud to serve Millsap, TX, and the surrounding areas with quality, comprehensive HVAC services. Since 1962, we’ve helped local homeowners take their indoor comfort to the next level. Whether you need installation, replacement, maintenance or repair, we’ve got you covered – 24/7! We offer a wide range of services, including AC, heating, plumbing, electrical and solar energy. We’re proud to offer a free second opinion so you know you’re always getting a fair deal. With Comfort Experts, you’ll never have to compromise on comfort. We know the ins and outs of heating, cooling and more so you don’t have to.
See what your Millsap, TX, neighbors are saying about our exceptional service. We’re here for you day and night, so when you need HVAC care you can trust, give us a call at (817) 341-5149!
Justin P. Is an incredible tech! Very knowledgeable and friendly. He did an amazing job and was very efficient. He was also great at keeping my floors clean while it was very muddy outside.
Justin did his usual good job, while I sat on porch drinking Lone Star.
Daniel was very knowledgeable and was able to repair our plumbing issue quickly.
Justin was a great guy. Knowledgable & courteous.
Very respectful and professional. Explained everything fully. Highly recommend.
JUSTIN DID HIS USUAL OUTSTANDING JOB!
Mark D and Tyler B were very professional. Tyler is in the learning phase but was very tentative in learning to do the right way.
We really appreciated Justin Penningtons attention to detail while servicing our HVAC. He was fantastic
Hunter was very professional and repaired our AC quickly. Thank you!
Wade and Zachary were very respectful and knowledgeable. Great work and very professional.
The guy that is being a job I'm proud of him. Thank you so much
Excellent service
They fix the issue
Great response and same day service!
Great service, came out for a quote, did the work as described.
I will always ask for Justin for anything I have done.
Both guys are very good mechanic and old time and did great job and have a good personality. The good employees this is from Chess
Justin always does a great job!
Justin has been here 3 or 4 times on my cooling and heating checks on my maintenance plan. He has always been knowledgeable and professional. He also puts up with my looking over his shoulder and questions.
Timely, very friendly and professional! Great experience.
Mark is very professional !!
Performed tune up on straight electric Lennox. Installed in 2013. All electrical connections are tight. Blower wheel has mild buildup. Mild biological growth inside system. Refrigerant levels were acceptable. Outside unit was very dirty causing compressor to pull high amperage. Thermostat cable outside was heavily sun damaged with slivers of exposed copper. Unit washed inside and out and waxed. Upon departure unit in cool and running.
4/23/26 Will need to return next Thursday to do work
Super tune up performed today on a propane furnace with straight cool condenser. All electrical connections are tight with no corrosion. Blower wheel and evaporator coil are clean. Refrigerant levels are in range. Compressor and condenser fan motor are acceptable. Outdoor unit was washed and waxed.
2019 Payne Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain has build up in P-trap Blower motor and wheel were acceptable Blower wires have biological growth build up Evaporator coil has heavy dust, dirt and Biological growth build up Supply plenum has slight biological growth build up 2019 Payne Straight Cool Checked and tightened all electrical connections Dual run cap was within manufacture range Primary electrical unit was acceptable Safety disconnect was poorly installed and breaker sparks every time it is turned on and off Refrigerant levels were showing low at this time due to evaporator coil being heavily compacted and weather conditions outside Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Recommended clear and treatment of drain, coil cleaning, compressor saver, safety disconnect replacement and UV s
Installed whole home surge protection
Perform tune up on Goodman package unit checked all electrical components make sure everything was tight make sure nothing was burned refrigerant levels were within range washed condenser coils and wax top of the system recommended surge protection
No show pauseing for now
Perform tune up on air handler and heat pump all components of air handler or within range customer recently changed filters blower motor has dust and dirt buildup on the fins UV lamp was out and passed replacement date checked all components of heat pump all components within range refrigerant levels for showing slightly low but the house indoor Temp 62 and did not have a real load at the time talked with customer about potential leak could not find any at this time recommended replacement UV lamp antimicrobial pant treatment and unit surge protection customer agreed to replace lamp and add antimicrobial pain treatment
Cannot access the property due to utility work pausing to return in the morning already spoke with customer Installed new 3\4 ball valve and 1in double chk to prevent back flow into municipal supply checked for leaks no leaks and checked for bk flow no back flow detected job complete
ill return tomorrow to install double chk and 3\4 ball valve please schedule first call
2020 Amana Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Heat strips were functional and within manufacture range Blower Motor and wheel were acceptable Evaporator coil was replaced recently UV system is functional 2020 Amana Heatpump Checked and tightened all electrical connections Dual run cap was within manufacture range Compressor saver is functional Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Recommended unit surge protection
Dismantled gas furnace removed front cover from evaporator coil and cleaned it using chemical cleaner removed blower motor from assembly and cleaned blower wheel assembly. Put the furnace back together and did a whole function check. During function check third furnace burner failed function test. dismantled burner and found coil cleaner that caused the blockage on the burner assembly ports. Cleaned burners and processed function test and system functions normally.
Super tune up performed today on a propane furnace with straight cool condenser installed in 2013. Blower wheel and evaporator coil are dirty and need to be cleaned. All electrical connections are tight with no corrosion. All amp draws are within spec. Refrigerant levels show as low but is most likely due to improper airflow across the coil due to it being dirty. Outdoor unit was washed and waxed. Need to return for rec work later this week. Customer is available after noon every day.
Generator maintenance performed today on a generac 24kw air cooled generator. Oil and oil filter changed. Air filter and spark plugs changed. Battery checks as good. Valve clearances check in tolerance. Performed function check. System running not ally at time of departure.
Completed STU for Main Area and master bedroom. Found failed dual run cap on bedroom system. Biological growth inside both systems. Exposed live wires in attic above main system. Missing paint on main system compressor appears to be from significant heat at one point.
Completed STU for Main Area and master bedroom. Found failed dual run cap on bedroom system. Biological growth inside both systems. Exposed live wires in attic above main system. Missing paint on main system compressor appears to be from significant heat at one point.
Completed STU for Main Area and master bedroom. Found failed dual run cap on bedroom system. Biological growth inside both systems. Exposed live wires in attic above main system. Missing paint on main system compressor appears to be from significant heat at one point.
Completed STU for Main Area and master bedroom. Found failed dual run cap on bedroom system. Biological growth inside both systems. Exposed live wires in attic above main system. Missing paint on main system compressor appears to be from significant heat at one point.
Heating tune up performed today on a Coleman heat pump with down flow air handler installed in 2016. All electrical connections are tight with no corrosion. Heat strips are pulling. Proper amperage. Reversing valve and defrost control board are working as they should. Refrigerant levels are in range. Outdoor unit was washed and waxed. Highly suggest adding a whole home surge protector to the main panel.
Came to house for electrical stove top having issues and causing lights to flicker got there and could not get the issue to happen but customer said lights were flickering and buzzing and breaker was also buzzing as well but could not get any of it to happen but did retighten connections and pull everything apart to take a look at it and everything did look fine but we did connections underneath stove top told customer if it happens again to give us a call back and I will come out there with no charge
This is to repair shower steamer and install shut down valves
Customer did not have filters. System has two 18x20x1 filters that needs to be changed as soon as possible. All electrical connections are tight with no corrosion. Evaporator coil and blower wheel are slightly dirty due to dirty air filters. Heat strips are pulling proper amperage. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed.
Super tune up performed today on a Ducane heat pump installed in 2024 with a Carrier air handler installed in 2019. All electrical connections are tight with no corrosion. X13 blower motor is acceptable. Blower wheel and evaporator coil are clean. Heat strips are pulling proper amperage. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Reversing valve and defrost control board are working as they should boutdoor unit was washed and waxed.
Capacitor on defrost board failed causing low voltage fuse to blow. Replaced board and ran system check. Left with system cooling
Brian needs a day to collect the info gathered and make a good estimate as well as find some good outside timers