Air Conditioning & Heating Services Near Millsap, TX
Comfort Experts is proud to serve Millsap, TX, and the surrounding areas with quality, comprehensive HVAC services. Since 1962, we've helped local homeowners take their indoor comfort to the next level. Whether you need installation, replacement, maintenance or repair, we've got you covered - 24/7! We offer a wide range of services, including AC, heating, plumbing, electrical and solar energy. We're proud to offer a free second opinion so you know you're always getting a fair deal. With Comfort Experts, you'll never have to compromise on comfort. We know the ins and outs of heating, cooling and more so you don't have to.
See what your Millsap, TX, neighbors are saying about our exceptional service. We're here for you day and night, so when you need HVAC care you can trust, give us a call at 817-341-5149 !
Recent Jobs and Reviews in Millsap, TX
Our Local Reviews by City
- Addison, TX (3)
- Aledo, TX (113)
- Allen, TX (10)
- Alvarado, TX (43)
- Annetta North, TX (1)
- Argyle, TX (22)
- Arlington, TX (401)
- Aubrey, TX (9)
- Aurora, TX (1)
- Azle, TX (80)
- Balch Springs, TX (2)
- Bedford, TX (39)
- Benbrook, TX (96)
- Bluff Dale, TX (3)
- Bowie, TX (2)
- Boyd, TX (14)
- Bridgeport, TX (3)
- Brock, TX (4)
- Burleson, TX (184)
- Carrollton, TX (32)
- Cedar Hill, TX (34)
- Chico, TX (1)
- Cleburne, TX (177)
- Colleyville, TX (22)
- Coppell, TX (11)
- Corinth, TX (15)
- Cresson, TX (10)
- Cross Roads, TX (3)
- Crowley, TX (76)
- Dallas, TX (93)
- Decatur, TX (8)
- DeCordova, TX (2)
- Denton, TX (61)
- DeSoto, TX (12)
- Duncanville, TX (2)
- Edgecliff Village, TX (1)
- Ennis, TX (2)
- Euless, TX (55)
- Everman, TX (7)
- Fairview, TX (3)
- Farmers Branch, TX (8)
- Flower Mound, TX (28)
- Forest Hill, TX (11)
- Fort Worth, TX (1441)
- Frisco, TX (30)
- Garland, TX (20)
- Glen Rose, TX (23)
- Glenn Heights, TX (1)
- Godley, TX (13)
- Gordon, TX (7)
- Graford, TX (8)
- Granbury, TX (329)
- Grand Prairie, TX (93)
- Grandview, TX (12)
- Grapevine, TX (25)
- Haltom City, TX (35)
- Haslet, TX (54)
- Highland Village, TX (14)
- Hudson Oaks, TX (49)
- Hurst, TX (29)
- Irving, TX (42)
- Itasca, TX (1)
- Jacksboro, TX (2)
- Joshua, TX (55)
- Justin, TX (11)
- Keene, TX (4)
- Keller, TX (44)
- Kennedale, TX (29)
- Krugerville, TX (2)
- Krum, TX (2)
- Lake Dallas, TX (2)
- Lake Worth, TX (4)
- Lakeside, TX (6)
- Lancaster, TX (1)
- Lantana, TX (4)
- Lewisville, TX (44)
- Lillian, TX (3)
- Lipan, TX (24)
- Little Elm, TX (13)
- Mansfield, TX (146)
- McKinney, TX (23)
- Mesquite, TX (4)
- Midlothian, TX (17)
- Millsap, TX (40)
- Mineral Wells, TX (72)
- Newark, TX (4)
- North Richland Hills, TX (36)
- Northlake, TX (7)
- Oak Point, TX (3)
- Odessa, TX (1)
- Palo Pinto, TX (6)
- Paradise, TX (8)
- Perrin, TX (7)
- Plano, TX (34)
- Ponder, TX (3)
- Poolville, TX (16)
- Prosper, TX (5)
- Providence Village, TX (2)
- Rainbow, TX (2)
- Raleigh, NC (1)
- Red Oak, TX (5)
- Rhome, TX (8)
- Richardson, TX (37)
- Richland Hills, TX (13)
- Rio Vista, TX (4)
- River Oaks, TX (6)
- Roanoke, TX (12)
- Rockwall, TX (1)
- Rowlett, TX (10)
- Royse City, TX (2)
- Runaway Bay, TX (2)
- Saginaw, TX (64)
- Sanger, TX (4)
- Santo, TX (2)
- Shady Shores, TX (3)
- Southlake, TX (19)
- Springtown, TX (95)
- Strawn, TX (7)
- The Colony, TX (12)
- Tolar, TX (10)
- Trophy Club, TX (14)
- Venus, TX (19)
- Watauga, TX (28)
- Waxahachie, TX (8)
- Weatherford, TX (551)
- Westlake, TX (1)
- Westworth Village, TX (7)
- White Settlement, TX (21)
- Willow Park, TX (40)
- Wylie, TX (1)
Job Locations and Reviews
Upon arrival system was down had no power to tstat, found Fuze was blown. Isolated issue to outdoor unit, found copper rubbed throught pressure switch causing Fuze to blow. Customer bought compressor saver Installed compressor saver
2012 gas package Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Blower motor and wheel have some dust build up Blower capacitor was within range Evaporator coil was heavily rusted Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Blower cleaning
2011 Goodman airhandler Checked and tightened all electrical connections Customer did not have extra filters for changing Blower motor and wheel were heavily compacted with dust and biological growth Evaporator coil was heavily compacted with dust and dirt Drain was clear and draining 2007 Carrier heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Blower cleaning, coil cleaning and uv light
Arrived to no cool. Found that the compressor is shorted to ground. R-22 condenser. Suggest replacement. Property is owned by Donna. She said she will get with Brett to figure out a solution. System is down. Invoice for service call sent to Donna.
Check Cody arrived to customer's home, I met Joey and he guided me inside to the thermostat and to the access to the indoor unit. I started my tune up inside at the indoor unit, the coil was clean the blower wheel was clean, I swapped out the filter, and the heat strips were pulling proper amperage. I then headed outside and wash the coil clean, and let it dry before taking my refrigerant readings. The electrical test for the inrush amperage for the compressor came back high likely because a hard start kit was not installed. The running amp test for the compressor and fan motor both came back well below manufacturer specifications according to the data tag. When taking the readings of the refrigerant charge my gauges were telling me that it was possibly undercharged but I believe it is because it is a cool day outside and there was no stress on the system, when taking the temperature split of the return and supply grills it was blowing very cold leading me to believe that the charger s
Thank you for sharing your positive experience with Comfort Experts and highlighting Aaron's exceptional service! We're delighted to hear that you had such a great AC service with us. If you have any other HVAC needs in the future, feel free to reach out. We appreciate your recommendation and look forward to serving you again!
Installed customer supplied frost free spigot
Cust compressor compromised Old r22 system Gave estimate for new refrigerant waiting on price of compressor Will follow up
Install 60k hz heat pump keep current filtration includes slab, disconnect, whip, drain pan, supply plenum, wiring for electric to heat pump
Upon arrival cust showed me where system was not draining properly and has done damage to the ceiling. Cust air handler is not level causing water to drain into plenums and all over insulation on interior of Airhandler. System has a refrigeration leak, performed complimentary leak test. Located leak in evaporator coil. System is not operating efficiently Primary drain is clogged. Left cust with repair estimate Cust wants to speak with CA about replacement
Upon inspection I found build up ofdust dirt and debris Recommended level 1 duct cleaning cust will follow up
Ran super tune up. System is only using heat pump even though it's setup for gas. Customer uses propane furnace for primary heat. Ran system in cooling and everything performed adequately. Let customer know about bio growth in supply plenum and evap coil. They want to install IAQ 200 at later time. Outdoor unit was performing good as well.
Service fee waived per Brian H. AC repair. Arrived to no cool. Indoor blower would turn on but outdoor condenser would not. Discovered the breaker to the outdoor unit in the main panel had tripped. Reset breaker and it tripped again immediately. Meg ohm tested to compressor to find that it had a short to ground. Compressor has failed and needs to be replaced.
Arrived for rec work Installed drain switch - Leak checked - none present Upgraded to IAQ300 System left in cooling at exit
Performed cooling tune up and system was running as normal. sold and installed IAQ 200. Customer wanted the IAQ 200 in the supply plenum and to move the value germicidal bulb in the evap coil. Customer also wants the add in a drain switch. I will be coming back tomorrow to move the value bulb and drain switch.
Arrived on site customer had a 1 year old water heater located in garage area not heating. Moisture had gotten into wire connection compartment and flipped breaker. Tested all wire connections and breaker closed wiring compartment everything working properly.
Install 48k hz indoor air handler keep current filtration includes code kit and drain pan
Air conditioning repair. Upon arrival customer stated system was not cooling properly, checked Refrigerant levels found that levels were low. Leak Checked Evaporator coil and found leak in coil. Set up appointment for CA Rob G Confirmed today 6-8
2012 Goodman dual fuel furnace Checked and tightened all electrical connections Customer recently changed filter Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Ignition system was functional All safeties are functional Blower capacitor was weak and out of manufacture range 2012 Goodman heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacturers range Primary electrical unit was acceptable Defrost is functional Refrigerant levels were acceptable at this time Condenser coil was acceptable Fan blades and motor were acceptable Washed coil from inside out Cleared debris from bottom of unit Waxed top of unit Per Brian H replace blower cap and bill to customer. Customer cat pay anything over 200 due to medicaid. Will have sons pay bill
2022 Amana airhandler Checked and tightened all electrical connections Customer did not have extra filter, stated will order one Blower motor and wheel were acceptable Evaporator coil was acceptable Uv system was non functional Supply duct to laundry room has supply duct laying on top causing airflow issues. Customer wanted to order filter and have us come out to take care of filter and adjust duct work for better airflow 2022 Amana heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacturers range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Condenser coil was acceptable Fan blades and motor were acceptable Washed coil from inside out Cleared debris from bottom of unit Waxed top of unit Recommended replacement of uv bulb, compressor saver and pan strip. Completed all Recommended work
Alec G. completed two annual heating system tune ups.
Cust didn't understand new thermostat, showed them how to use it System is operating correctly. Not a call back
During inspection verified that systems were working properly Spoke to customer about recommendations for the systems that would help the health and reliability of the systems and she said if I could email the estimate so she could talk to husband about it but that the best bet was gonna be the uv germicidal lights and that also she said they had talked about having us back out later to get pricing on redoing the ducts in the home Left customers house with systems operating properly
During inspection verified that system was working properly Spoke with customer about some recommendations for the system and he decided he wanted to go ahead and swap out the cap so system would be fine running Left customers house with system operating properly
Sandy is going to redo the financing and add this to it