Highland Village AC & Heating Services
The purpose of your heating, air conditioning and ventilation system is to provide a comfortable and safe environment inside your home. This could be anything from keeping your home heated or cooled at your preferred temperature to improving the indoor air quality and circulation of your home to help fight against respiratory and other illnesses. Can you guarantee that your unit is running at its full potential and successfully providing the ideal comfort and safety for your Highland Village home? If you answer “no” to this question it is time to have your unit inspected. Call us today at 817-341-5149 to schedule your inspection!
Highland Village AC Repair & Replacement
If your unit is unable to be repaired and has to be replaced, we’re here to quickly get a new unit put in so you can get back to the comfort you deserve. All you have to do is choose a new system! We provide a wide range of HVAC units to choose from so we know that you will be able to find a new system that caters to your needs.
Our 5-star online reviews show that we are dedicated to customer satisfaction. We have made it our goal to leave you saying that you had a good experience with our company. We take pride in the work we do and always back our work with a 100% customer satisfaction guarantee. You will always be left satisfied and we will always leave knowing we have successfully assisted your family with your Highland Village AC repair needs.
Here For All Your HVAC Needs
Comfort Experts, Inc. has made it our mission to keep Highland Village families comfortable all year long and assure that your home is a safe environment. No matter the issue with your heating and cooling systems, we’re here to help. By offering AC inspection and repair, we can diagnose a malfunction quickly and fix the problem, returning your system to peak performance.
In addition to heating and cooling, we specialize in plumbing and electrical services so you don’t have to worry about hunting down multiple contractors. We take care of all your HVAC systems from start to finish. For the most comfortable call you’ll ever make, we’ll be here 24/7 at 817-341-5149 !
Recent Jobs and Reviews in Highland Village, TX
Our Local Reviews by City
- Addison, TX (3)
- Aledo, TX (113)
- Allen, TX (10)
- Alvarado, TX (43)
- Annetta North, TX (1)
- Argyle, TX (22)
- Arlington, TX (401)
- Aubrey, TX (9)
- Aurora, TX (1)
- Azle, TX (80)
- Balch Springs, TX (2)
- Bedford, TX (39)
- Benbrook, TX (96)
- Bluff Dale, TX (3)
- Bowie, TX (2)
- Boyd, TX (14)
- Bridgeport, TX (3)
- Brock, TX (4)
- Burleson, TX (186)
- Carrollton, TX (32)
- Cedar Hill, TX (34)
- Chico, TX (1)
- Cleburne, TX (177)
- Colleyville, TX (22)
- Coppell, TX (11)
- Corinth, TX (15)
- Cresson, TX (10)
- Cross Roads, TX (3)
- Crowley, TX (77)
- Dallas, TX (93)
- Decatur, TX (8)
- DeCordova, TX (2)
- Denton, TX (61)
- DeSoto, TX (12)
- Duncanville, TX (2)
- Edgecliff Village, TX (1)
- Ennis, TX (2)
- Euless, TX (55)
- Everman, TX (7)
- Fairview, TX (3)
- Farmers Branch, TX (8)
- Flower Mound, TX (28)
- Forest Hill, TX (11)
- Fort Worth, TX (1443)
- Frisco, TX (30)
- Garland, TX (20)
- Glen Rose, TX (24)
- Glenn Heights, TX (1)
- Godley, TX (14)
- Gordon, TX (7)
- Graford, TX (8)
- Granbury, TX (329)
- Grand Prairie, TX (93)
- Grandview, TX (12)
- Grapevine, TX (25)
- Haltom City, TX (35)
- Haslet, TX (54)
- Highland Village, TX (14)
- Hudson Oaks, TX (49)
- Hurst, TX (29)
- Irving, TX (42)
- Itasca, TX (1)
- Jacksboro, TX (2)
- Joshua, TX (55)
- Justin, TX (12)
- Keene, TX (4)
- Keller, TX (44)
- Kennedale, TX (29)
- Krugerville, TX (2)
- Krum, TX (2)
- Lake Dallas, TX (2)
- Lake Worth, TX (4)
- Lakeside, TX (6)
- Lancaster, TX (1)
- Lantana, TX (4)
- Lewisville, TX (44)
- Lillian, TX (3)
- Lipan, TX (24)
- Little Elm, TX (13)
- Mansfield, TX (146)
- McKinney, TX (23)
- Mesquite, TX (4)
- Midlothian, TX (17)
- Millsap, TX (41)
- Mineral Wells, TX (72)
- Newark, TX (4)
- North Richland Hills, TX (36)
- Northlake, TX (7)
- Oak Point, TX (3)
- Odessa, TX (1)
- Palo Pinto, TX (6)
- Paradise, TX (8)
- Perrin, TX (8)
- Plano, TX (34)
- Ponder, TX (3)
- Poolville, TX (16)
- Prosper, TX (5)
- Providence Village, TX (2)
- Rainbow, TX (3)
- Raleigh, NC (1)
- Red Oak, TX (5)
- Rhome, TX (8)
- Richardson, TX (37)
- Richland Hills, TX (13)
- Rio Vista, TX (4)
- River Oaks, TX (6)
- Roanoke, TX (12)
- Rockwall, TX (1)
- Rowlett, TX (10)
- Royse City, TX (2)
- Runaway Bay, TX (2)
- Saginaw, TX (64)
- Sanger, TX (4)
- Santo, TX (2)
- Shady Shores, TX (3)
- Southlake, TX (19)
- Springtown, TX (95)
- Strawn, TX (7)
- The Colony, TX (12)
- Tolar, TX (10)
- Trophy Club, TX (14)
- Venus, TX (19)
- Watauga, TX (28)
- Waxahachie, TX (8)
- Weatherford, TX (552)
- Westlake, TX (1)
- Westworth Village, TX (7)
- White Settlement, TX (21)
- Willow Park, TX (41)
- Wylie, TX (1)
Job Locations and Reviews
This system is over amping out side. The cap tested in tolerance and the fan motor is running at 1 amp. The system could use a hard start kit and uv system to keep system Evap coil clean and air fresh. Sustem is cleaned and ready for cooling.
Plumbing inspection Home is 4 years old Plumbing is in great condition. Some corrosion on hot side supply line on water heater No leaks or broken fixtures at this time
Plumbing inspection Home is 4 years of age Plumbing system is in great shape No leaks or broken fixtures at this time
Arrived for AHC Replaced filter Recommend filtering at unit due to fresh air duct bypassing the current filter box Drains clear Furnace fine Blower and coil dusty Installed IAQ200 to eliminate biological growth contamination from system and air Washed condenser coil Capacitors, motors, and refrigerant fine System left in cooling at exit
After looking at his panel a replacement is recommended and he does seem very interested but at the time he needs to think about it allocate funds I will be making an estimate and sending that to him
Tech arrived at a warranty tuneup. Upon inspection, the capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The drain was clear and bleach was poured. Tech filter was dirty and replaced. The blower area was a little dirty. The Delta was within range. The heating system reached complete ignition. The customer was informed of recommendations today. He would like a quote for a panel replacement and whole home surge protector. Office was contacted but it was after hours. The system was functioning upon departure.
After arriving and getting to the electrical panel I checked and tightened all connections including grounds neutrals and mains I checked plugs in the kitchen dining room and wash room and all of them were wired correctly and gfci's were present in the proper locations, I did talk to them about a surge protector but they were not interested in getting one at this time
Tyler L completed an electrical etu when I opened up the panel I found no particular problems all of the connections were tight he had gfci's afci's no search protector but it was all wired correctly and then I tested plugs inside of the home all of which tested correctly he had GFC eyes in the correct spots I also tested the asci and talk to him about a surge protector he did talk about how they probably weren't going to be in the house for far too long so he wasn't very interested in getting one I did rebuttal with how they are becoming a mandatory thing nowadays so he might have to put one in if you would ever sell the house
On arrival the system was running and cooling. The indoor unit had a clean blower, coil, and clear drain lines. The unit produced a 20 degree delta. The outdoor unit passed all electrical tests. I recommended a drain treatment strip so that the customer would not need to treat his drain lines monthly and a whole home surge protector to protect his new house and ac system. Thanks for choosing comfort experts and have a great day!
Tech arrived at a warranty tune-up. Upon inspection the capacitor was within specs. The contactorless board was functioning. The Delta was within range. The filter was a little dirty. The drain line was backed up. It was flushed and drained slowly afterwards. The UV light was not functioning. The water heater had corrosion on the fittings. The customer was informed of recommendations today. He will evaluate concerns himself. The system was functioning upon departure.
Tech arrived at a membership service call. Upon arrival the customer mentioned that the outside unit was making a strange noise last night. The system was functioning at this time. The capacitor was within specs. The condenser coils were hosed off to assist with air flow across the coils. The contactor was scorched and was replaced today. There was no observed surge protection. The system was functioning upon departure.
Texh arrived at warranty service call. Upon inspection, the condenser coils were very dirty. The customer described having issues with the high pressure switch tripping. The condenser coils were hosed off to assist with air flow across the coils. The capacitor was within specs. The system was functioning upon departure.
Upon arrival system was in working condition. Looking at the indoor unit all electrical connections and components are good. Blower and coil are clean. Drains are clear and flowing. Filter is clean. Could benefit from a uv light but rejected work. Looking at the outdoor unit , all electrical connections and components are good. Capacitor is within tolerance. Amp draws are acceptable. Refrigerant levels are acceptable. Could benefit from compressor saver but rejected work. Cleaned unit from inside out. Left system in working Condition. Thank you for choosing comfort experts.
Install 42k gas hz with high efficiency filtration, reroute drain lines to front of system
Upon arrival for service system off. Inspected system. Found primary electrical control not functioning. Due to age of system recommended speaking with engineer before repairs. Customer agreed and scheduled for Saturday June 3rd 12-3.
STU complete. Customer needed a new UV bulb - replaced. Customer needs to order AA210 filter, showed cust how to install. System fully functional. Recommended Attic tent. Customer expressed interest in Solar and will reach out to us when ready.
Tech arrived for a Armstrong Air system tune-up. There was a ride along employee present. Upon inspection, capacitor was within specs. The contactor was in working condition. The amperages were within range. The condenser coils were hosed off to assist with air flow across the coils. The Delta was within range. There was no observed surge protection. The filter was clean. The blower area was a little dirty. The drain system had a pan safety but no drain switch. The drain was clear and vinegar was poured. The customer was informed of recommendations today. The system was functioning upon departure.
upon arrival for tune up on 7 year old American standard gas furnace it was on and heating. Inspected outdoor unit. Fan and compressor amp draw within unit specifications. Capacitor within tolerance. Cleaned unit. Refrigerant pressure good. Inspected indoor unit. Blower has dust buildup. Coil clean. Delta good. Drain line clear. Furnaces ignited and heated properly. Noted while in attic customer has radiant barrier insulation and no other insulation. Recommended adding insulation to support radiant barrier. Customer agreed and scheduled insulation for April 25th.
#iaq upon arrival for tune up on 6 year old Lenox system it was on and cooling. Inspected outdoor unit. Fan and compressor amp draw within unit specifications. Capacitor within tolerance but barely. Refrigerant pressure good. Inspected indoor unit. Blower has slight dust buildup. Coil clean. Drain line clear. Recommended replacement of capacitor due to how close to out of tolerance it is.
Arrived for AHC #Solar 2 year old Goodman furnace system Furnace functional but has dust build up already - up flow system does not have room for a polarized filter upgrade - recommended upgrading the merv rating of the april aire filter to merv 13 or better to try and catch more of the dust getting past their current 210 Merv 11 Bio growth present on the duct board in the plenum - UVC/UVV system will be installed to eliminate the growth Drains are clear Filters swapped Washed the condenser coil Capacitor is in tolerance Customer stated he saw the unit do some sort of start and stop the other day - condenser started fine and ran for 15 mins with no issues - compressor starting amp draw measured 131 - - per unit data plate amp draw is too high - should be under 114 - recommended a hard start kit to lower amp draw to recommended levels as the core sense module may be causing issues with the start - customer will try to get a video if he sees it happen again Refrigerant levels are fine
Checked both inside and outside units. Downstairs system performed good. Amp and capacitor draws are in range. Inside is good as well. Blower is clean. Upstairs unit is fried. Both inside and outside for upstairs has had a surge hit. Pictures in summary
System giving code EE0 which means lockout due to repeated unsuccessful attempts, reset code system made it all the way to the hot surface igniter heating up but there was no ignition due to the gas valve being bad, replaced gas valve under parts and labor warranty
System giving code EE0 which means lockout due to repeated unsuccessful attempts, reset code system made it all the way to the hot surface igniter heating up but there was no ignition due to the gas valve being bad, replaced gas valve under parts and labor warranty
System giving code EE0 which means lockout due to repeated unsuccessful attempts, reset code system made it all the way to the hot surface igniter heating up but there was no ignition due to the gas valve being bad, replaced gas valve under parts and labor warranty
System giving code EE0 which means lockout due to repeated unsuccessful attempts, reset code system made it all the way to the hot surface igniter heating up but there was no ignition due to the gas valve being bad, replaced gas valve under parts and labor warranty