Heating & Air Conditioning Services Near Springtown
Residents in Springtown have relied on Comfort Experts, Inc. to troubleshoot, detect, and repair their air conditioning problems for years. Because of our customers in Springtown, we have become a well-respected name when it comes to AC repair. If you need AC repair, replacement, or maintenance, give us a call today! We will have your unit up and running in no time. We also specialize in heating, plumbing and electrical services so you don’t have to shop around for multiple contractors.
If you have been a homeowner for any length of time, then you know the importance of maintaining the AC unit in your home. Here are some ways your air conditioner can benefit from regular service from Comfort Experts.
Longer lifespan – Prevent major breakdowns by checking on smaller issues. You can preserve the life of your AC unit for a few more years by doing this. Reduction in repair costs – Regular maintenance of your unit will show you minor problems early and you can get them fixed right away. Avoiding regular maintenance checks can cause you to miss small issues that eventually grow into big problems that cost you a lot more money. Reduced energy costs – Your unit will work more efficiently and less hard to pump out cold air, resulting in less cost to you in the long run. The better your unit performs, the lower your energy bill will be. Comfortable temperature – The more often you have your unit checked, the lower the chance of breakdowns. If your unit is working as it should all the time, you will have consistent and comfortable temperatures indoors.
Springtown AC Repair All Year Long
Regular AC service in Springtown is most important between seasons. They help ready the unit for temperature and weather changes which are very common in Springtown, and regular AC repair can help to find potential problems before they become major headaches.
Whether you have experienced a complete system failure or just started noticing some minor problems with your unit, give us a call. Some of the reasons you might need to call us for AC service include:
Strange rattling noises coming from the unit. AC not turning on. AC not blowing cold air. Strange smells coming from AC or vents. AC does not turn on or off, even though the thermostat says it should.
We can also do complete AC installations, energy efficiency checks, and air quality evaluations. Because we want to make your house as comfortable and as energy efficient as possible, we will do whatever it takes to make that happen. Call Comfort Experts 24/7 at 817-341-5149 !
Local Reviews
for Springtown, TX
Our Reviews by City
Semi annual visit
Phyllis - Springtown, TX 76082
SpringtownTX76082 32.9175-97.63
Excellent service
Don - Springtown, TX 76082
SpringtownTX76082 32.9825-97.6425
Excellent service
Matthew - Springtown, TX 76082
SpringtownTX76082 33.0025-97.8125
Service
James - Springtown, TX 76082
Mark did a great job. Thanks.
SpringtownTX76082 32.9475-97.67Excellent service!!
Wendy - Springtown, TX 76082
SpringtownTX76082 32.9175-97.6325
Excellent service
Blake - Springtown, TX 76082
Friendly, knowledgeable, and efficient! Thanks Jeff!
SpringtownTX76082 32.995-97.67Air unit
Britt - Springtown, TX 76082
Service agent was great
SpringtownTX76082 32.9825-97.645Excellent Service
Randy - Springtown, TX 76082
Dennis was excellent, he was very professional, extremely knowledgeable found and replaced a bad contactor.
SpringtownTX76082 32.955-97.6175Responsive & professional, great value!
Steve - Springtown, TX 76082
I used Hobson AC to install a Soft Start device (that I had already purchased) to my 4-ton outdoor unit. Kellen Mullinnix was prompt, very professional and quickly installed the Soft Start, which lowered my LRA from 144.2, down to only 15.6!!! This will allow my generator to easily run the 4-ton AND my entire house now!
SpringtownTX76082 32.99-97.7125Excellent Service
Tommy - Springtown, TX 76082
Mike was so great! He answered all my questions and addressed all my concerns. He had a great professional attitude and was so easy to talk to. Would absolutely use again, and I’ll ask for Mike!
SpringtownTX76082 32.9375-97.69Excellent
Evelyn - Springtown, TX 76082
SpringtownTX76082 32.9975-97.65
Normal operation
Thomas - Springtown, TX 76082
We left our house vacant and returned during 100+ degree summer heat, the A/C took all day to cool to 80 degrees so we called for a checkup. Turns out that’s normal since the technician found nothing wrong.
SpringtownTX76082 32.9675-97.675Great service
Robert - Springtown, TX 76082
SpringtownTX76082 32.93-97.6925
Excellent service as always
Colleen - Springtown, TX 76082
Very nice, professional, knowledgeable person.
SpringtownTX76082 32.98-97.6725Great service
Robin - Springtown, TX 76082
SpringtownTX76082 32.96-97.68
Comfort Air
Hans - Springtown, TX 76082
Fine service 10 rating
SpringtownTX76082 32.925-97.6025Excellent education
Jose - Springtown, TX 76082
Very knowledgeable and very helpful
SpringtownTX76082 33.0125-97.7875Dependable service
Mary - Springtown, TX 76082
SpringtownTX76082 32.975-97.7675
Excellent Service
Matthew - Springtown, TX 76082
Straight to the point, straight forward
SpringtownTX76082 32.975-97.7475Very courtous
Pete - Springtown, TX 76082
Very professional, has a good knowledge of work.
SpringtownTX76082 32.9675-97.685Great
Javier - Springtown, TX 76082
Wyatt C did a great job
SpringtownTX76082 33.0125-97.8025Outstanding
Jim - Springtown, TX 76082
SpringtownTX76082 32.9425-97.6725
Great
Jim - Springtown, TX 76082
Very professonal. Kept us well informed and explained everything very well. Will request him every time we need your service
SpringtownTX76082 32.9425-97.6725Very professional
Hans - Springtown, TX 76082
SpringtownTX76082 32.925-97.6025
Great Service
Matthew - Springtown, TX 76082
Courteous and polite during visit. Straight forward on recommendations and pricing
SpringtownTX76082 32.975-97.7475Mike S.
Tested all components all measured within ratings and specs. Refrigerant level is normal. Washed and cleaned condenser. Filter has been changed recently.
Tyler L.
Completed an electrical evaluation that is GFCI in the garage that keeps tripping is connected to three outlets outside the very well could be the problem I gave him the price for a and a diagnostic said he has to think about it
Mike S.
Tested all components all measured within ratings and specs. Refrigerant level is normal. Washed and cleaned outdoor unit. Changed filter.
Justin P.
2018 Rheem Gas Furnace Main living area Checked and tightened all electrical connections Changed customer provided filter Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Heat exchanger was acceptable All safeties are functional 2020 Rheem Gas Furnace Master bedroom Checked and tightened all electrical connections Changed customer provided filter Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Heat exchanger was acceptable All safeties are functional
Tyler L.
Tyler L completed an electrical evaluation two breakers had gone bad I replaced both and sent him an estimate to install a customer's fan
Justin P.
2022 Goodman airhandler Checked and tightened all electrical connections Customer recently changed filter Drain was clear and draining poured a gallon of water down Blower motor and wheel were acceptable Evaporator coil was acceptable Heating elements were functional 2022 Goodman Straight Electric Dual run capacitor was within manufacturers range Electrical connections were acceptable Refrigerant levels were acceptable at this time Condenser coil was acceptable Fan blades and motor were acceptable Washed coil from inside out Waxed top of unit Recommended compressor saver declined for now
Ian C.
Cust was complaining of a noise that sounded like running water, found vent partially closed opened and the horrid noise stopped Checked water meter for possible leaks, no leaks
Diego M.
Upon arrival system was in working condition. Looking at the indoor unit all electrical connections and components are good. Blower is dirty. Coil is clean. Drain lines are clear and flowing. Looking at the outdoor unit all electrical connections and components are good. Capacitor within tolerance. Amp draws acceptable. Refrigerant levels acceptable. Unable to clean water since customer doesn't have water right now. Left system in working condition.
Mark W.
2018 Goodman Air Handler Checked and tightened all electrical connections Filter was acceptable Blower wheel and motor were acceptable Evaporator coil was acceptable Uv bulb needed replacement, Replaced uv bulb Heatstrips were functional 2018 Goodman heatpump Dual run capacitor failed on fan side, replaced capacitor Electrical connections were acceptable Defrost is functional Refrigerant levels were acceptable at this time Condenser coil was slightly impacted with dust and debris Fan blades and motor were acceptable Unit surge had failed replaced unit surge
Tyler L.
Tyler L completed etu checked over the customers electrical panel looked great have absolutely no problems with it I checked over his plugs he did not have GFC eyes installed I talked to him about it and that's something that he was wanting to do himself I also peek my head in the attic to make sure everything was good the light switch cover is broken I did recommend that you get that replaced as well along with getting GMC eyes put in the bathrooms and the kitchen
.
One of the wind turbines got leak, took it off and redo it.
Ian C.
Contactor compromised Swapped system operating Compressor amp draws high Filters dirty
Mike S.
Outdoor coil looked like it hadn't been cleaned for a long period of time covered in debris compressor was more than likely overheating and switching to thermal so I washed and cleaned outdoor unit system has been on and cooling since I arrived and upon departure. No other issues detected.
Mike R.
System has a open start circut. Replaced cap 35 5 system online cooling like nvr before.
Zak L.
Arrived for rec work Lifted and supported unit with wooden base underneath the head - could not support with manufacturer supports due to lack of placement relative to in wall studs Stretched drain lines out underneath the house to eliminate sagging and water accumulation preventing proper flow Mounted drain lines Tested with a gallon of water - drains fine Left unit in cooling at exit
Zak L.
Arrived for service eval Mini split head is not level so the water wont drain towards the drain pan Could not communicate with landlord due static on the line Per Ryan this repair should be done with 2 people - one to hold the mini split the other to remount Dispatch please communicate with landlord
Tyler L.
Electrical to HVAC Tyler L has completed an electrical evaluation through looking at a generator software I determine that the battery was no longer usable and upon opening the corroded on both terminals he said that he would like to replace the battery himself but on Wednesday the 6th I will have a HVAC tech come out and give him proper pricing on new ducting or a mini split depending on the outcome of their conversation he also might need assistance reprogramming the generator once the battery has been placed inside
Ryan S.
5 head mini split, cleaned condenser coil, refrigerant levels in range, cleaned inside filters. Looked at 121 not 119, tenant was not home.
Mark D.
Rheem symtraigh cool condenser with downflow air handler installed in 2019. All electrical connections are tight with no corrosion. Blower motor is working as it should with no side to side movement in bearings. Blower wheel is slightly dirty. Evap coil is clean. 45/10 dual run capacitor is within tolerance. Contactor is clean with no pitting. Compressor saver is installed. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Technician cleaned outdoor unit by back flushing the coils and cleaning off the panels and applied a coat of wax to protect unit from the sun. Customer is interested in whole home surge protection. Breaker panel is a cutler hammer.
Ian C.
Upon arrival for bedroom and bathroom or not, cooling efficiently have minimal air flow. I found multiple kinks and duct work. Customer told me that he was having more insulation blown into Is attic. Explain to customer that we need to take advantage of this opportunity, so it gives him a more efficient ducting system. Customer agreed install will come tomorrow to reroute and seal duct work and plenums
Tyler L.
Tyler L completed electrical evaluation found that they had no room for a surge protector but everything inside of the panel was wired correctly voltages tested nicely connections were very tight I tested plugs inside of the kitchen bathrooms and living areas all of which were wired correctly gfci's were present I tested the main disconnect outside voltage was good but they had some connections with wire caps that have melted away she told me that a goat had stepped or chewed on the line causing this to happen and her husband fixed it in the past but now due to the temperature of the problem has resurfaced I did offer my services but she said that her husband could fix it
Mike S.
Upon arrival system was down, thermostat read 99 set at 70. Indoor airhandler running. After evaluation of condenser, found dual run cap was under manufacture range. Replaced cap everything running as should. Left system in cooling customer confirmed
.
48k heat pump outdoor with disconnect and whip
Aaron W.
U its cap was dead ,replaced and left system cooling
Mark D.
Three year old Carrier heat pump with air handler. All electrical connections are tight with no corrosion. X13 blower motor is running strong. Blower wheel and evap coil are clean. 70/7.5 dual run capacitor is weak and needs to be replaced soon. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Delta T is at 18 degrees.