Mckinney AC & Heating Services

The purpose of your heating, air conditioning and ventilation system is to provide a comfortable and safe environment inside your home. This could be anything from keeping your home heated or cooled at your preferred temperature to improving the indoor air quality and circulation of your home to help fight against respiratory and other illnesses. Can you guarantee that your unit is running at its full potential and successfully providing the ideal comfort and safety for your Mckinney home? If you answer “no” to this question it is time to have your unit inspected. Call us today at 817-341-5149 to schedule your inspection!

Mckinney AC Repair & Replacement

If your unit is unable to be repaired and has to be replaced, we’re here to quickly get a new unit put in so you can get back to the comfort you deserve. All you have to do is choose a new system! We provide a wide range of HVAC units to choose from so we know that you will be able to find a new system that caters to your needs.

Our 5-star online reviews show that we are dedicated to customer satisfaction. We have made it our goal to leave you saying that you had a good experience with our company. We take pride in the work we do and always back our work with a 100% customer satisfaction guarantee. You will always be left satisfied and we will always leave knowing we have successfully assisted your family with your Mckinney AC repair needs.

Here For All Your HVAC Needs

Comfort Experts, Inc. has made it our mission to keep Mckinney families comfortable all year long and assure that your home is a safe environment. No matter the issue with your heating and cooling systems, we’re here to help. By offering AC inspection and repair, we can diagnose a malfunction quickly and fix the problem, returning your system to peak performance.

In addition to heating and cooling, we specialize in plumbing and electrical services so you don’t have to worry about hunting down multiple contractors. We take care of all your HVAC systems from start to finish. For the most comfortable call you’ll ever make, we’ll be here 24/7 at 817-341-5149 !

Local Reviews
for Mckinney, TX

Comfort Experts Inc. Rated 5.0 out of 5 stars based on 19 customer reviews

Our Reviews by City

Aledo, TX (95)
Azle, TX (62)
Boyd, TX (10)
Hurst, TX (25)
Lipan, TX (20)
Plano, TX (25)
Venus, TX (15)


Map of McKinney, TX 75070

maintenance




Review of Comfort Experts Inc.

Blake did a great service, he explain in detail what we needed and why we needed it.

McKinneyTX75070 33.19-96.745

Map of McKinney, TX 75071

Excellent Service




Review of Comfort Experts Inc.

Timely, professional, and helpful

McKinneyTX75071 33.205-96.725

Map of McKinney, TX 75070

Good work




Review of Comfort Experts Inc.

McKinneyTX75070 33.19-96.645

Map of McKinney, TX 75069

Very Professional




Review of Comfort Experts Inc.

McKinneyTX75069 33.205-96.62

Map of McKinney, TX 75070

Always professional




Review of Comfort Experts Inc.

Ryan was very professional, friendly, and efficient. His explanation of what he found was very clear.

McKinneyTX75070 33.1675-96.655

Map of McKinney, TX 75071

Great service




Review of Comfort Experts Inc.

McKinneyTX75071 33.24-96.64

Map of McKinney, TX 75070

Great service, Devyn!




Review of Comfort Experts Inc.

Devyn quickly diagnosed and resolved our AC issue. Great service.

McKinneyTX75070 33.175-96.69

Map of McKinney, TX 75070

Very quick and efficient. Polite young man




Review of Comfort Experts Inc.

👍

McKinneyTX75070 33.18-96.6825

Map of McKinney, TX 75071

Great Service




Review of Comfort Experts Inc.

Always good service and professional technicians

McKinneyTX75071 33.205-96.725

Response from Comfort Experts Inc.:

Thank you for trusting us to get the job done. Your 5-star review and gratitude mean a lot to us!


Map of McKinney, TX 75070

Great professional service




Review of Comfort Experts Inc.

Casey did a thorough job troubleshooting and repairing our A/C system. He also checked the entire system to make sure everything was working properly.

McKinneyTX75070 33.1725-96.65

Response from Comfort Experts Inc.:

Thank you Robert!


Great service




Review of Comfort Experts Inc.

Very nice, friendly, knowledgeable rep! Very good service and explanation.

McKinneyTX75070 33.1675-96.655

Awesome service




Review of Comfort Experts Inc.

Job well done. Very satisfied with the service Casey provided

McKinneyTX75071 33.2275-96.65

Totally Awesome




Review of Comfort Experts Inc.

Simon was an awesome tech who explained everything before he started working and then went over everything throughly afterwards. We've used this company for 10+ years and have always had excellent customer service both on the phone and in person.

McKinneyTX75071 33.28-96.62

As far as I know, Tyler did an excellent job. He said everything he checked out was fine.




Review of Comfort Experts Inc.

McKinneyTX75070 33.18-96.655

Great service




Review of Comfort Experts Inc.

McKinneyTX75070 33.1725-96.65

Great Service




Review of Comfort Experts Inc.

The tech did good.

McKinneyTX75069 33.16-96.5375

They did a very clean and thorough install and they also, went over everything completely ly understood. We appreciate their professionalism and thei




Review of Comfort Experts Inc.

We are very happy

McKinneyTX75070 33.16-96.6925

Great Service




Review of Comfort Experts Inc.

Erasmo did an awesome job.

McKinneyTX75070 33.18-96.725

All-around Super




Review of Comfort Experts Inc.

Accommodating schedule, on-time, courteous & pleasant, did an excellent job of servicing, as well as I could tell.

McKinneyTX75069 33.2175-96.62

colby.finch@acgenius.com

colby.finch@acgenius.com

On arrival the system was running and cooling. I installed the new fan motor and capicator. Once finished the system turned back on and resumed cooling. Thanks for choosing comfort experts and have a great day!

Near Mesa Valley Dr, McKinney, TX 75071
Blake  B.

Blake B.

Tech arrived at a membership tune-up. Upon inspection the capacitor was within specs. The contactorless board showed no errors. The system had surge protection. There is whole home surge protection at the main panel. The Superheat was very low. Possible TXV malfunction. The Delta was a little low. The filter was dirty and replaced. The drain was draining slowly. A treatment strip was added today. The water heater flue pipe was misaligned. Attempts were made to center the flue but were unsuccessful. The customer was informed of recommendations today. The customer would like a plumber to evaluate the water heater and other house plumbing fixtures. She is available Monday, she has to leave at 1:30pm. The repair needed is a possibLe safety concern. We will pause the call for a visit from a plumber.

Near Sonnet Dr, McKinney, TX 75071
colby.finch@acgenius.com

colby.finch@acgenius.com

Need to return next Wednesday afternoon with a 1/6 hp 825 rpm condenser fan motor. I do not have one in the van so I am setting it up as rec work.

Near Mesa Valley Dr, McKinney, TX 75071
Tyler L.

Tyler L.

9/20/23 Will be returning the 26th with added work a new cover plate and a half switch half duplex switch cover plate for the new light

Near Inland Ln, McKinney, TX 75072
Brock S.

Brock S.

Returning Wed 20th to finish

Near Inland Ln, McKinney, TX 75072
Ian C.

Ian C.

Furnace operating efficiently and safely, blower wheel clean and operating efficiently, compressor Amp draws acceptable Fan motor Amp draws acceptable System clean and sfe

Near Inland Ln, McKinney, TX 75072
Blake  B.

Blake B.

Tech arrived at a warranty tuneup. Upon inspection the capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The filter was dirty and replaced. The blower area was dirty. There was growth throughout the system. The UV bulb was not functioning. The house power went out during the inspection. The customer was informed of recommendations today. House power was still off upon departure.

Near Pvt Rd 5065, McKinney, TX 75071
Blake  B.

Blake B.

Tech arrived at a service call. Upon inspection, the capacitor was out of tolerance. The contactor was buzzing loudly and had rusted terminals. These two items were replaced today and the system regained functionality.

Near Ridge Point Ct, McKinney, TX 75072
Blake  B.

Blake B.

Tech arrived at a membership tune-up. Upon inspection, the capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The filter was dirty and replaced. The Delta was within range. The drain was clogged and there was water in the secondary drain pan. The drain was cleared and a treatment strip was added to help keep the drain system clean. The insulation levels were low.

Near Cross Fence Dr, McKinney, TX 75069
Blake  B.

Blake B.

Tech arrived at a warranty service call. Upon inspection, the thermostat was blank. The furnace control board was recieving high voltage. The neutral was not recieving properly continuity through the transformer. The high voltage connections were tightened and the system regained functionality. The Delta was 21 degrees. The UV bulb was replaced and a treatment strip was added to help keep the drain system clean. The system was functioning upon departure.

Near Inland Ln, McKinney, TX 75072
Diego M.

Diego M.

Upon arrival system was in working condition. Client stated that company that installed units diagnosed and bad txv and recommended recovery refrigerant and putting in new refrigeratant cause it was ' contaminated ' told client that if refrigerant was contaminated, system would not have been able to work 5 yrs. Left system In working condition. Client had invoice.

Near Vineyard Ln, McKinney, TX 75070
Diego M.

Diego M.

Upon arrival both systems were in working condition. Looking at the indoor units all electrical connections and components are good. Blower and coils are clean. Drain lines are clear and flowing. Looking at the outdoor units , all electrical connections and components are good. Both capacitors are within tolerance. Downstairs unit could benefit from compressor saver. Refrigerant levels are good. Amp draws are good. Cleaned both units inside out. Left both systems in working condition. Thank you for choosing comfort experts.

Near Vineyard Ln, McKinney, TX 75070
Zak L.

Zak L.

Arrived for service eval Error code for open start circuit Dual run cap testing at 0 Hard start kit blown Replaced both System operational Ran for 10 minutes to verify refrigerant is at good levels UV bulb is out of date and should be replaced or upgraded to a 5 year UV system No surge protection present on furnace - recommended to protect control board - install at furnace or onto the house panel All repairs approved by the homeowners son

Near Sonnet Dr, McKinney, TX 75071
Blake  B.

Blake B.

Tech arrived at a membership service call. Upon inspection the wet switch was tripped. The wet switch was relocated. The drain was tested and found to be clogged. The drain was cleared and a treatment strip was installed. The system was functioning upon departure.

Near Cheverny Dr, McKinney, TX 75070
Steven S.

Steven S.

Upon arrival for service system on and cooling. Customer states thermostat losing power off and on. Inspected safteys on system. Found partial clog in drain lines which would cause power loss then slowly drain after 30-40 min allowing power to return. Cleared and sanitized Drain line. Left system on and cooling.

Near Inland Ln, McKinney, TX 75070
Blake  B.

Blake B.

Tech arrived at a service call. Upon arrival it was late. The customer mentioned that both systems were not functioning properly. Upstairs system- the Delta was 10 degrees. The condenser coils were very dirty. There was a 10 degree Superheat, 3 degree Subcool. A leak search was performed. There was a possible leak at the interior portion of the condenser coil at the bottom. Downstairs system- there was a L6 code for Open Start Circuit Lockout. Capacitor was out of tolerance and was replaced today. The customer previously purchased a premium capacitor. The capacitor was replaced under warranty. The condenser coils were dirty and were replaced today. The customer was informed of recommendations. He will contact his warranty company about the upstairs system. The systems were functioning upon departure.

Near Sandalwood Dr, McKinney, TX 75070
jose.govea-soto@acgenius.com

jose.govea-soto@acgenius.com

Quoted 36k coil only $4,184

Near Ridge Point Ct, McKinney, TX 75070
Zak L.

Zak L.

Arrived for service eval System low on refrigerant Filter fine Blower is good Coil leaking Tons of bio growth in the supply plenum Unit disconnect breaker failed while on site CA set for 5/31 10-12

Near Ridge Point Ct, McKinney, TX 75070
Cody J.

Cody J.

Complete STU on R22 system 09, upstairs unit only heatpump. Heating was not check per customer request. No obvious issues or know issues with heating per customer. No obvious signs of heating issues. Cooling mood was checked. 18 degree delta, indoor coil clean, blower motor, squirrel cage and blower capacitor ok. Blower cap is 15 mfd within manufacturer specs. Drain functioning as should. Poured 1 gallon of water through drain without issues. Customer provided air filter changed. Outdoor unit fan amps, compressor amps ok, fan motor was pretty warm indicating its weak. Capacitor was ok. Within manufacturer specs. Outdoor condenser full cotton tree blooms. Unit was cleaned and washed. Refrigerant levels slightly low. Saturation levels above freezing. R22 system. Recommend replacing contactor, customer declined. Technician will need a 8 ft ladder to access upstairs unit.

Near N College St, McKinney, TX 75069
Blake  B.

Blake B.

Tech arrived for a membership tune-up. Upon inspection the capacitor was within specs. The contactor was audibly buzzing. This item was replaced today. The Delta was within range. The system did not appear to have surge protection. A unit surge protector was installed today. The filter was replaced. The drain system was found to be clogged when testing. Multiple clogs were found and removed from the drain system. A drain treatment strip was also added to help keep the drain system clean. The customer inqured about having the disposal and a couple faucets replaced. The customer was given a quote and will call us back at a later time once he decides how he would like to proceed. The system was functioning upon departure.

Near Old Field Dr, McKinney, TX 75070
Steven S.

Steven S.

Upon arrival for service customer states noticed system not cooling yesterday. System was blowing air but outside unit was not coming on. System off at breakers. Turned system on and system came on and cooled. Cleaned system. Drain lines clear. Refrigerant pressure good. Electrical conections good. Capacitor within tolerance. Left system on and cooling at departure.

Near Jocelyn Way, McKinney, TX 75071
Mike  S.

Mike S.

Arrived on site greeted cx thanked them for continued membership and business. Moved to outdoor package unit tested all components all measured within ratings and specs. Blower wheel, coil and drain are clean and clear at this time. Refrigerant level is normal. Washed and cleaned unit. Uv light bulb was not working offered replacement. Cx politely declined today.

Near Pvt Rd 5065, McKinney, TX 75071
Aaron  W.

Aaron W.

Outdoor unit is operating within specifications, refrigerant levels are good at this time, capis out of tolerance ,indoor unit is operating within specifications, safety checked and are good, drain line is clear at this time, replaced cap, custo,er needed to talk to someone else about other recommendations

Near Heritage Palms Trail, McKinney, TX 75070
Jeffrey  B.

Jeffrey B.

Arrived at location. Home owner not present. Someone else was sent to let me inside. She then left. Inspected indoor unit. Electrical connections tight. Temperature delta within acceptable range. Blower wheel clean. Coil clean and in good condition. Changed filter. Inspected outdoor unit. Electrical connections tight. Refrigerant charge good. Coil in good condition. Washed coil. Fan and compressor Amp draw good. Capacitor in spec.

Near Jocelyn Way, McKinney, TX 75071
Zak L.

Zak L.

Arrived for CTU #IAQ 4 year old goodman furnace Replaced filter Sitting water in the primary drain pan - declined drain clear today Slightly dusty blower Coil is clean Dust and biological growth in the supply plenum - UV system air scrubber recommended for clean air 20 degree delta Washed condenser coil Capacitor in tolerance Running amp draw is in range Compressor starting amperage over manufacturer specs and should be lowered with a compressor saver kit - rated up to 112 measured at 140

Near Wadkins Ct, McKinney, TX 75070
Expert Quality & Service
Request Service
servicedetailscustomerreturningschedule
How Can Comfort Experts Inc Help You Today?
Details Regarding Your Request...
Max. file size: 4 MB.
Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What day would you prefer?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 817-341-5149 .

Back Next