Perrin AC & Heating Services
The purpose of your heating, air conditioning and ventilation system is to provide a comfortable and safe environment inside your home. This could be anything from keeping your home heated or cooled at your preferred temperature to improving the indoor air quality and circulation of your home to help fight against respiratory and other illnesses. Can you guarantee that your unit is running at its full potential and successfully providing the ideal comfort and safety for your Perrin home? If you answer “no” to this question it is time to have your unit inspected. Call us today at 817-341-5149 to schedule your inspection!
Perrin AC Repair & Replacement
If your unit is unable to be repaired and has to be replaced, we’re here to quickly get a new unit put in so you can get back to the comfort you deserve. All you have to do is choose a new system! We provide a wide range of HVAC units to choose from so we know that you will be able to find a new system that caters to your needs.
Our 5-star online reviews show that we are dedicated to customer satisfaction. We have made it our goal to leave you saying that you had a good experience with our company. We take pride in the work we do and always back our work with a 100% customer satisfaction guarantee. You will always be left satisfied and we will always leave knowing we have successfully assisted your family with your Perrin AC repair needs.
Here For All Your HVAC Needs
Comfort Experts, Inc. has made it our mission to keep Perrin families comfortable all year long and assure that your home is a safe environment. No matter the issue with your heating and cooling systems, we’re here to help. By offering AC inspection and repair, we can diagnose a malfunction quickly and fix the problem, returning your system to peak performance.
In addition to heating and cooling, we specialize in plumbing and electrical services so you don’t have to worry about hunting down multiple contractors. We take care of all your HVAC systems from start to finish. For the most comfortable call you’ll ever make, we’ll be here 24/7 at 817-341-5149 !
Local Reviews
for Perrin, TX
Our Reviews by City
Excellent Service and Personel
Broken Promises Sanctuary - Perrin, TX 76486
Always wonderful. KInd, knowledgeable , clean, efficient and reliable. Highly recommend
Excellent service
Linda - Perrin, TX 76486
Excellent services!
Broken - Perrin, TX 76486
Tyler was a very knowledgeable and friendly service technician. We always have a pleasant experience when ever we call Comfort Experts!
Great job
Suesan - Perrin, TX 76486
Brady was a very nice man and got his work done quickly, even though it was nearly 7 at night. Great job
Fast and knowledgeable
Robert - Perrin, TX 76486
Mark D.
Main home: gas furnace with heat pump installed in September of last year. Customer states system froze up. Second time in a month. Refrigerant levels are in range. Delta t is 20 degrees. Technician repaired a seal around the flashing for the furnace flue pipe. Daylight was visible through the flashing. Customer says that the system freezes up after a storm. Water could have possibly been leaking in through the faulty seal and shorting the blower causing the outside unit to run but the blower was not. Performed function check and system worked as it should on this visit. If it continues it is an intermittent problem that needs to be addressed. Performed super tune up on kennel system. All electrical connections are tight with no corrosion. PSC blower wheel and capacitor are acceptable. Blower wheel and evap coil are clean. Customer did not have filter to change out. Heat strips are in range. 70/5 dual run capacitor is within tolerance. Compressor and condenser fan motor are working a
Mark D.
Amana heat pump with propane furnace installed in 2022. Arrived to no cool, customer states that unit was freezing up. Removed air filter from to find that it was very dirty and restricting air flow. Checked refrigerant levels without filter and all levels are within range. All electrical connections are tight with no corrosion. Ecm blower motor is acceptable. Blower wheel and evap coil are clean. 45/5 dual run capacitor is within tolerance. Condenser fan motor and compressor are running as they should. Compressor saver, UV system, and a surge protector are all installed on the unit. Customer has ordered new filter and will replace it as soon as it comes in.
Mike S.
Capacitor out of rating recommend replacement before failure. All other components indoor and outdoor measured within ratings and specs. Refrigerant level is normal. Washed and cleaned outdoor unit. Changed filter.
Aaron W.
Arrived to system blower not pushing air due to dust build up,cleaned and left system cooling but blowernmotor still not pushing air,custo,er is taking up with home warranty
Mark D.
Arrived to no cool. Discovered failed dual run capacitor. Changed 70/7.5 capacitor and system started and ran. System running in cool upon departure.
Mike S.
2018 ruud gas furnace Checked all electrical connections Changed customer provided filter Drain was clear and draining Blower motor was acceptable blower wheel had some build up Evaporator coil was acceptable Supply vents had growth Supply plenum had growth 2018 ruud straight cool Dual run capacitor was within manufacturers range Electrical connections were acceptable Refrigerant levels were acceptable at this time Fan motor and blades were acceptable Condenser coil was acceptable Washed unit from inside out Waxed top of unit
Mike S.
Upon arrival system was on and cooling. Checked every component on air Handler. Found nothing, checked every component on compressor found nothing wrong
Mike S.
Contactor was not passing power through to compressor replaced contactor with new. System is now on and cooling.
Wyatt C.
The primary electrical contactor was compromised due to fire ants getting into the system. Did full evaluation on the system freon levels were acceptable at this time, system was healthy offered Maintenance agreement customer declined. Customer interested in solar Brian will reach out and discuss what customer wants.
Tyler L.
Check the main panel and the panel at the Kennels main panel is a little old oxidized and has some Rust talked to the gentleman about replacement as well as the fact that the surge protector was doubled a breaker that said it was on the AC 15 amp The new code is 2356
Mike S.
5/12/23 installed SUPCO Freeze Protection Control, Model SFPC, to protect the air conditioning coil from freezing in addition to the time delay relay in series with the Y call from thermostat. Unit is functioning currently. Ran unit for 15 minutes. Checked draining of drain. Drain is ok. Wet-switch was tripped upon arrival but no obvious signs of water or leaking. Switch was reset and functioning. 4/28/23 Having pressure/ airflow issues, ordering additional parts, Brian H is looking for a certain line temperature sensor and will send the info to parts department when he finds it
javier.falcon@acgenius.com
Pilot light was out, relit pilot light
.
Install Seer 2 60k upflow propane gas system with 90% furnace, high efficiency filtration
Mark D.
House unit: R-22 unit. Gas furnace limit switch tripped causing blower to come in but nothing else. Reset switch and system turned on in cool. Low on refrigerant. Customer is interested in replacing unit. Office unit: call wires were very brittle and broken in more than one spot. Scheduled to come back and run new call wires to outdoor unit. Was able to splice wires and got it running for now but customer wants it to be done with new wires. Shop unit: r-22 unit. Very dirty in evap coil, blower wheel and ducting. Blower motor has lots of movement in bearings. Blower capacitor is weak. System has no filter. Dual run capacitor is acceptable. Compressor and condenser fan motor are acceptable. Outdoor coil is damaged from what looks like a weed eater. Need to return this week to run new call wires to outdoor unit.
Wyatt C.
Performed a STU blower wheel was heavily impacted by sediment Evaporator coil was impacted by sediment Blower motor was acceptable Blower capacitor was within manufacturer range Heating elements were functional and within manufacturer range Electrical connections were acceptable Dual capacitor was within of manufacturer range Condenser coil was acceptable Refrigerant levels were a little low subcooling of 6 r22 system Washed the unit from inside out Waxed the top of the unit Electrical connections were acceptable Fan blades and motor were acceptable
riley.hobson@acgenius.com
Hooked up oven
Brian H.
Repaired supply water to horse trough in pasture
Tyler B.
Kennel house system not working due to flu pipe not being sealed so water dripped down and tripped the wet switch, I did not have. Anything to seal the flu pipe and the customer didn’t either, because this is unrelated to previous issues the customer paid a service fee
Tyler B.
Kennel house system not working due to flu pipe not being sealed so water dripped down and tripped the wet switch, I did not have. Anything to seal the flu pipe and the customer didn’t either, because this is unrelated to previous issues the customer paid a service fee
Tyler B.
Kennel house system not working due to flu pipe not being sealed so water dripped down and tripped the wet switch, I did not have. Anything to seal the flu pipe and the customer didn’t either, because this is unrelated to previous issues the customer paid a service fee
Tyler B.
Kennel house system not working due to flu pipe not being sealed so water dripped down and tripped the wet switch, I did not have. Anything to seal the flu pipe and the customer didn’t either, because this is unrelated to previous issues the customer paid a service fee
Brady F.
Installed light box and changed switch
Tyler B.
Nest not controlling dual fuel properly, made nest only use gas heat, ordering outdoor dual fuel thermostat
Tyler B.
Nest not controlling dual fuel properly, made nest only use gas heat, ordering outdoor dual fuel thermostat
Tyler B.
Nest not controlling dual fuel properly, made nest only use gas heat, ordering outdoor dual fuel thermostat