Lakeside AC & Heating Services
The purpose of your heating, air conditioning and ventilation system is to provide a comfortable and safe environment inside your home. This could be anything from keeping your home heated or cooled at your preferred temperature to improving the indoor air quality and circulation of your home to help fight against respiratory and other illnesses. Can you guarantee that your unit is running at its full potential and successfully providing the ideal comfort and safety for your Lakeside home? If you answer “no” to this question it is time to have your unit inspected. Call us today at 817-341-5149 to schedule your inspection!
Lakeside AC Repair & Replacement
If your unit is unable to be repaired and has to be replaced, we’re here to quickly get a new unit put in so you can get back to the comfort you deserve. All you have to do is choose a new system! We provide a wide range of HVAC units to choose from so we know that you will be able to find a new system that caters to your needs.
Our 5-star online reviews show that we are dedicated to customer satisfaction. We have made it our goal to leave you saying that you had a good experience with our company. We take pride in the work we do and always back our work with a 100% customer satisfaction guarantee. You will always be left satisfied and we will always leave knowing we have successfully assisted your family with your Lakeside AC repair needs.
Here For All Your HVAC Needs
Comfort Experts, Inc. has made it our mission to keep Lakeside families comfortable all year long and assure that your home is a safe environment. No matter the issue with your heating and cooling systems, we’re here to help. By offering AC inspection and repair, we can diagnose a malfunction quickly and fix the problem, returning your system to peak performance.
In addition to heating and cooling, we specialize in plumbing and electrical services so you don’t have to worry about hunting down multiple contractors. We take care of all your HVAC systems from start to finish. For the most comfortable call you’ll ever make, we’ll be here 24/7 at 817-341-5149 !
Local Reviews
for Lakeside, TX
Our Reviews by City
They do a good job.
Norman - Lakeside, TX 76135
Prices for work is high. They try to up sell for things every time they come out. I know they have to make more and more money to stay in business, but it gets a little irritating.
Response from Comfort Experts Inc.:
Thanks for the glowing review!
Great service!
Jessica - Lakeside, TX 76135
Ryan did a great job! Helped us get ahead of some minor issues we were having. Changed the filter in the attic. He was fast and friendly and knowledgeable! Will use them again in the future!
Fast Service
Mike - Lakeside, TX 76135
..
Steven - Lakeside, TX 76108
The AC tech was knowledgeable, and did inform me of what needed to be done. I learned what might be done with my system to improve it, which is nice. But not for $108. The fan was dirty, so Im going to clean it. The capacitor is failing, so Im going to replace it. One of the drains was dangling, so Im going to tie it up. There are exposed low voltage lines that are exposed, that I will cover up. I guess I expected a slight tune up, but there wasn't really anything done to the system other than advice. I do appreciate it, but I most likely would not pay for the service again, based on cost.
Great Service, Fast Response Time
Mike - Lakeside, TX 76135
Aaron W.
Outdoor unit is operating, refrigerant levels are good at this time, coil is serverly dirty recommend coil deep clean,indoor unit operating, drain line is flowing but is flowing slowly, recomended customer clear drain line said they will blow out with a air compressor ,left system cooling
Mark D.
Amana gas furnace with straight cool condenser installed in 2019. All electrical connections are tight with no corrosion. Ecm blower motor is running strong. Blower wheel and evap coil are clean. Dual run capacitor and primary motor start are in tolerance and working as they should. Compressor and condenser fan motor are acceptable. Refrigerant and airflow levels are in range. Technician suggests replacing the UV bulb for improving air quality and adding a compressor saver for energy savings and longevity of the system.
Aaron W.
Customer didn't answer
Mark D.
Arrived to no cool. Discovered 30/5 dual run cap reading 2.2/4.8. Changed capacitor, performed hard reset on system and was reading 16 degree delta T upon departure.
Aaron W.
Arrived to system not cooling ,upon inspection of system I found that the refrigerant were low ,customer didn't have time for me to perform a leak search so I topped off system with free pound of refrigerant as promotion says, and left system cooling
Alec G.
Upon arrival to customers house system was cooling System 1 Blower wheel clean EVAP clean Drain line had some buildup Electrical connections good Filter changed Cap within tolerance Contactor good Electrical connections good Refrigerant levels good Coil clean System 2 Blower wheel clean EVAP coil clean Drain line clear Electrical connections good Filter changed Cap within tolerance Contactor good Refrigerant levels good Coil clean Fan motor good Compressor good System 3 Blower wheel clean EVAP coil clean Electrical connections good Filter changed Drain line clear Cap below tolerance Contactor good Refrigerant levels good Coil clean Compressor good Fan motor good Compressor saver good Got with customer about swapping that cap out and went ahead and got it installed for him Left customers house with system cooling
Adam J.
Completed my thorough inspection, both attic units were inspected, UV systems are now working properly, coils were inspected, drain was checked and would advise pouring bleach once a month during the summer to maintain clear drains. Both outdoor unit were cleaned and both capacitors are within rating. I'd advise installing compressor saver for both your outdoor units to lower the starting amps giving your compressors an easy start while prolonging the life of your compressors. Treatment strips
Ryan S.
Performed Stu, system operation is normal, cleaned condenser, changed filter, system components in tolerance. Uv bulbs are out of effective age and need to be replaced. Talked to customer about solar #solar
Steven S.
upon arrival and tune up on Frankenstein system with 10 year old Goodman inside and 8 year old Ameriair outside unit it was on and heating. System is straight electric. Inspected outdoor unit. Fan amp draw high. Compressor amp draw within unit specifications. Refrigerant pressure good. Clean outdoor unit. Inspected indoor unit. Blower has dust buildup. Coil clean. 1 out of 3 heat strips is not functioning. System is not keeping up with house with only 2 functioning heat strips. Customer asked for pricing on replacement of heat strips. Recommended speaking with engineer about system do to age and general wear of the system. Offered complementary energy audit. Customer agreed and scheduled for Saturday March 25th 10-12. Left system on and heating.
javier.falcon@acgenius.com
Shower head was turned off not broken All other plumbing fixtures were good in the house. Customer wants automatic emergency shutoff installed on 2 water heater Unknown pricing
Dennis C.
4 year old Amana heat pump, thermostat blank, batteries bad replaced batteries system is operating normally at this time.
Ryan S.
Performed ahc, system operation is normal, 3 year old gas Lennox. Cleaned out condenser and washed coil, filter clean. Capacitor in tolerance, refrigerant levels in range, compressor pulling over lra, recommend compressor saver, customer has rm-2 uvv / uvc installed, bulbs are over 2 years old recommend replacing to get full utility out of bulbs. Customer signed up on copper membership
Tyler B.
HTU performed today, indoor unit ignition components are functioning properly and the inducer motor is pulling proper amperage.
Tyler B.
HTU performed today, indoor unit ignition components are functioning properly and the inducer motor is pulling proper amperage.
Tyler B.
HTU performed today, indoor unit ignition components are functioning properly and the inducer motor is pulling proper amperage.
Tyler B.
HTU performed today, indoor unit ignition components are functioning properly and the inducer motor is pulling proper amperage.
Wyatt C.
Customer saw steam coming from the top of her unit informed her and educated her on the process of the defrost told her it was completely normal check the defrost board and all the components inside everything was good
Wyatt C.
Completed the tune ups on both systems Replaced the UV systems and transformers for both systems and got new bulbs installed. Everything else was functional and with manufacturer ranges. Customer ordered filters and I said I would come back and install them for them
Mark D.
Goodman gas furnace with straight cool condenser installed in 2019. All electrical is good. 45/5 dual run capacitor and contactor are good. UV bulb is still on but over 3 years old. Gave customer estimate to replace. X13 blower is good and has clean blades. Airflow and refrigerant levels are satisfactory
Yaz G.
Completed tune up. Outdoor unit capacitor in tolerance. Fan and compressor pulling normal amps. Refrigerant level good. Indoor unit blower wheel clean. Drain clear. Filter ok. Coil has no corrosion. Turned system back up to 80 before leaving as house is being sold
Joel B.
Did a STU/ evaluation on system,on arrival found indoor unit running and the outside unit off,chekced capacitor and found dual run capacitor was weak, replaced under P&L WARRANTY, changed filter,flushed drain,refrigerant levels are good, customer verified unit was working properly when leaving A
Dennis C.
Tripped drain switch, cleared drain, system is operating at this time.
Dennis C.
Minor electric repair, broken R wire at thermostat, system is operating normally at this time.
Tyler B.
HTU performed today, indoor unit ignition components are functioning properly and the inducer motor is pulling proper amperage. Filter is clean, customer has not replaced ultra violet bulb since installation, recommended replacing. Customer declined
Tyler B.