HVAC, Plumber and Electrical Service Near Corinth, TX
At Comfort Experts Inc., we understand how critical air conditioning, plumbing, heating and electric services are for your home. That is why we provide 24/7 services to our customers in Corinth, TX, so you never have to worry about not being taken care of. Our team members are highly trained and experienced in HVAC services. Our plumbing department offers an array of services such as sewer line cleaning, water heater installation and other necessary jobs. Our electrical team provides a wide variety of service options in order to give your home a much-needed boost and get things back up and running. Established in 1962, you can count on our expertise and experience when it comes to all your home comfort needs – and you will always get the satisfaction that you deserve. Read through some of the reviews below to discover just how many lives have been improved by this quality service!
Air Conditioning Repair in Corinth, TX
Every homeowner will eventually need AC repair someday. After all, your AC unit is just a machine, and on top of that, we all know how summertime can be in Texas… Sun, sun, and more sun!
Imagine this: you return home after a full working day and all you want is to chill out and refresh yourself. You turn on your air conditioning unit and it simply doesn’t work. Even if you want to leave it for the next day, there is no way you can stand the heat. It is time to call for an emergency AC repair.
Comfort Experts is your fastest and most reliable solution when it comes to AC services. We are happy to offer you AC services in your Corinth home.
Comforts Experts Means Professional AC Services in Corinth
If you need AC services in Corinth, TX, look no further than our team. With Comfort Experts Inc., all the hassle is taken away from you. We provide professional service and are happy to take on any projects regarding AC services to help you be as comfortable as possible in your home.
Call us now to take advantage of our fast and reliable service. We will come to your home and take a professional look at all problems you may have and give you our best opinion about all the issues your air conditioning unit is facing. We also are happy to provide free second opinions on another air conditioner quote.
A Company You Can Trust
Have you ever considered that your power bills may be much higher because of your HVAC’s performance? In fact, the first sign your AC unit is not performing the way it should actually be your last electric bills and the overall air quality of your house.
Don’t worry, help is on the way. Now all Corinth residents can rely on our exceptional and dedicated team not only for your AC service but also for the maintenance of your equipment as well. With our maintenance agreement, you will have less to worry about with your AC units because we’ll be keeping an eye on them regularly.
Additionally, we will inspect your entire home in order to improve the overall quality of air. We will closely look at your central air unit to help prevent any issues in the future. Not only will we help you prevent a costly and often avoidable repair, but we will also help you reduce your electric bill and improve the overall air quality of your house.
Local Reviews
for Corinth, TX
Our Reviews by City
Excellent Service, Great Delivery
Hector - Corinth, TX 76210
2nd unit purchased this year and another quick and professional delivery. Ensured everything was up to code and went the extra mile to ensure they met requirements. 1st unit purchased had an issue they resolved asap and under warranty and expecting the same with this unit. Great communication and ensured any questions I had were answered right away. Gave instructions for care (unit is more maintenance-free than the older unit) and ensured my Nest unit was configured properly. Hauled away old unit and ensured everything was clean before leaving. Overall, very pleased with the process, and while, yeah, it's not cheap, at least I won't have to worry about these units for another decade or so.
CorinthTX76210 33.13-97.08



Heating inspection
Trish - Corinth, TX 76210
CorinthTX76210 33.16-97.08




Outstanding service!
Hector - Corinth, TX 76210
Mark was friendly, knowledgeable and provided a very thorough review of plumbing in my home. I was very happy to have him come in and discuss what he encountered, as part of my contract, including what could be life-saving recommendations for rusty gas connections. One more reason I enjoy working with Comfort Experts!
CorinthTX76210 33.13-97.08



Great Service
Edith - Corinth, TX 76210
Did an Awesome job. Professional and politeness.
CorinthTX76210 33.14-97.0575



Thorough and amazing price!
Trish - Corinth, TX 76210
Highly recommend.
CorinthTX76210 33.16-97.08



Great
Sandra - Corinth, TX 76210
CorinthTX76210 33.155-97.0725




Service
William - Corinth, TX 76210
Dennis good, situation bad
CorinthTX76210 33.135-97.055
Response from Comfort Experts Inc.:
Thank you for bringing this to our attention- we are sorry to hear of the level of service you received. We will dig deeper into why this happened so that we can do better in the future.




Great Service
Blair - Corinth, TX 76210
Jordan was curteous and friendly while helping us out today and I thank you guys so much for his help
CorinthTX76210 33.1375-97.0775



Excellent customer service
Teresa - Corinth, TX 76208
CorinthTX76208 33.15-97.045




Tech was great
William - Corinth, TX 76210
Was not informed about delay in arrival arrived at 8, left at midnight Dispatch did not keep me informed Tech was great(5 stars)
CorinthTX76210 33.135-97.055




Jeffrey B.
Arrived at location and spoke with home owner. Inspected indoor unit. Electrical connections tight. Excessive dust buildup in supply duct. Recommended duct cleaning and blower pull and clean. Home owner interested in duct cleaning, may contact office in near future to schedule. Blower capacitor in spec. Temperature delta within acceptable range. Filter changed. Coil clean and in good condition. Inspected outdoor unit. Electrical connections tight. Fan and compressor Amp draw good. Refrigerant levels good. Capacitor in spec. Fan motor housing rusting. Coil washed. Coil in good condition. Surge protection not active. Recommended replacement, home owner agreed.

Mike R.
Tune up showed an extremely drity return I recommed a duct cleaning and a uv light to maintain a healthy system. Other wise system is new and works great.

Gavin V.
Checked inside and systems. Downstairs system is well. Amp draws and capacitor readings are within range. Blower and coil are clean. Ducts are clean. Upstairs unit amp draws and capacitor tolerances are within range, start up amp draw is higher than max. Blower and coil is clean ducts are clean. Talked to customer about surge protection and hard start kits. Systems left in working order, changed thermostat batteries

Steven S.
#iaq upon arrival for tune up on 3 year old diakan gas furnace system it was on and heating. Inspected outdoor unit. Unit is inverter board. Inverter board has no hot spots. power draw on system good. Cleaned unit. Refrigerant pressure good. Inspected indoor unit. Blower has slight dust buildup. Coil clean. Furnace ignited and heated properly. Drain line clear. Recommended whole home surge protector for protection of home. Left system on and heating.

Blake B.
Tech arrived for a cooling tune-up*2. It was cold and rainy. There was a ride along employee present. Upstairs system- the capacitor was within specs. The contactor was in working condition. The condenser coils were dirty and were hosed off to assist with air flow across the coils. There was no observed surge protection. The filter was dirty and replaced. The ductwork was dirty. The drain was clear and bleach was poured. The Delta was 19 degrees. Downstairs system- the capacitor was within specs. The contactor was in working condition. The contactor was audibly buzzing. The condenser coils were dirty and were hosed off to assist with air flow. There was no observed surge protection. The filter was dirty and was replaced. The drain system was clear and bleach was poured. The Delta was 21 degrees. The customer was informed of recommendations. The customer decided to move forward with preventative maintenance including contactor replacement for the downstairs system and drain treatme

Blake B.
Tech arrived at a 1st year tuneup. The capacitor was within specs. The contactor was in working condition. The condenser coils were extremely dirty and were hosed off to assist with air flow across the coils. There were 2 filters on the system. The one at the attic unit was removed. The Delta was within range. The drain was clear. The blower area was a little dirty. There was no observed surge protection. The water heater was evaluated. The system appeared to be a 2008 model. There was no pan beneath the heater and there was corrosion on the fittings. Customer was informed of the recommendations and was given quotes. The customer decided not to move forward today. The customer was informed that a laps in membership may result in the loss of labor warranties. The system was functioning upon departure.

Dennis C.
Downstairs: 2 year old Amana gas system, duct cleaning, system is operating normally at this time. Replaced filter provided. Upstairs: 3 year old Amana gas system, duct cleaning. System is operating normally at this time. Water heater. Calling home Warranty company

riley.hobson@acgenius.com
Found some debris lodged inside of the inducer motor. After clearing the debris, the furnace fired right up.

Blake B.
Tech arrived for a HTU on the Upstairs system. <br> The capacitor was within specs. The contactor was in working condition. The Delta was within range. The filter was a little dirty. There was no replacement today. The customer was given order information. The drain was clear and bleach was poured. The heating system reached complete ignition. The systems did not appear to have Surge Protection. <br> <br> The customer decided to move forward with surge protection today. Surge Protectors were added to both systems. The items were installed, tested, and functioning.<br> <br> The system was functioning upon departure.

.
Install Dual fuel 24k horizontal upstairs with high efficiency filtration, whip, disconnect and drain pan

Steven S.
Upon arrival for tune up system on and heating. Inspected indoor unit. Blower has slight dust buildup. Coil clean. Drain line clear. Inducer motor amp draw within unit specifications. Ignitor and flame sensor clean. Inspected outdoor unit. Fan and compressor amp draw within unit specifications. Capacitor within tolerance. Refrigerant pressure good.

Blake B.
Tech arrived at a HTU. Upon inspection the the outside inverter board appeared to be functional. The condenser coils were clean. The Delta and refrigerant was at acceptable levels. There did not appear to be surge protection present. The filter was dirty and replaced. The drain system was clear and bleach was poured. The door safety switch was bypassed. This was fixed. The heating system reached complete ignition. The customer will think about repairs and will let us know. The system was functioning upon departure. Customer paid by check.

Blake B.
Tech arrived for a tune up. Upon inspection the capacitor was within specs. The contactor was in working condition. The condenser coils were clean. The Delta and refrigerant was at acceptable levels. The filter was relatively clean. The ducts were a little dirty. The drain system was clear and bleach was poured. The system did not appear to have Surge Protection. The customer was given information about repairs and memberships. The customer will pass at this type. The system was functioning upon departure. The customer paid with cash.

Steven S.
Upon arrival for tune up systems on and cooling. Inspected indoor units. Blowers and coils dusty. Drain line clear. Filters need to be changed. Inspected outdoor units. Upstairs unit capacitor out of tolerance. Downstairs unit capacitor within tolerance. Fan and compressor amp draws within unit specifications. Units heavily matted. Recommended replacement of capacitor. Customer declined at this time. Customer refused to pay service fee to technician. Wanted to pay to office. Called dispatch. They said they would collect.

Mark W.
Replace gas drip leg on water heater replayed all gas lines to make sure all appliances are working properly Call customer at the end of October to get this work done Company visor is set to come out on October 6 from 12 to 3

Blake B.
Tech arrived for a STU *2. Upstairs system- The capacitor was close to being out of tolerance and was replaced. The contactor was in working condition. The Delta, amperages, and refrigerant was at acceptable levels. The filter was dirty and replaced. The drain system was clear and bleach was poured. Downstairs system- The capacitor tested within specs. The contactor was in working condition. The compressor was pulling high amperage and was loud when starting up. A compressor saver was installed to help combat high amperage. There was a scorched HERM wire upon arrival. This wire was replaced as well as the spade. This situation should be monitored. The Delta and refrigerant was at acceptable levels. The filter was dirty and replaced. The drain system was clear and bleach was poured. The customer decided to add unit surge protection to the outside units. All surge lights were functioning after installation. Both systems were functioning upon departure and set temps were returned

riley.hobson@acgenius.com
Tech arrived for a service call and CTU. Downstairs system- The outside unit was running upon arrival. The blower motor was making a loud noise and not spinning. The motor was replaced and the system regained functionality with a 21 degree Delta and refrigerant was at acceptable levels. Upstairs system- The contactor was a little rusted. The condenser coils were dirty. The capacitor was close to being out of tolerance. Customer said she would wait on this repair until next visit. The drains were checked and clear. The filters were replaced. The condenser coils were hosed off to assist with air flow. Both systems were functioning upon departure.

J H.
Customer was not home. Dispatch attempted contact several times to no avail. I waited 30 minutes. Left a bit and card on front door.

Yaz G.
Completed 2 system tune up. Both outdoor units capacitor in tolerance. Fan and compressor pulling normal amps. Washed both outdoor coils. No issues with indoor units. Filter are ready to be changed. Drain lines clear. Evaporator coils have no signs of corrosion. Blower wheels clean on both.

sergio.varelaj@acgenius.com
Install 30k heat pump upflow with slab, disconnect, whip and programmable thermostat

Jordan B.
Thoroughly inspected the system, found Dual run blown up, lizard burned up connected to the back of the defrost control board, condenser fan has hot spots, evaporator coil rusted and the air handler has a substantial amount of biological growth. Due to the age/EPA regulations and efficiency of the system, recommended upgrading to something reliable with warranties behind it. Customer is meeting with an advisor tomorrow morning.

Zak L.
Arrived for CTU x 2 Downstairs unit Charge good Amp draws good Cap in tolerance Coil dirty Indoor Drain clear Filter fine Cant open coil door due to lineset mounted to it Blower slightly dusty upstairs unit Iutdoor Charge good Cap in tolerance Coil dirty Electricals tight Indoor Filter clear Drains clear Cap in tolerance

riley.hobson@acgenius.com
Arrived for NC tune up? System operational - very little airflow upstairs - unit tripped HPC (thermostat alert) twice in the last week but cst reset breaker both times Outdoor Cap in tolerance Coil VERY dirty - washed out per advertisement flyer No error code on board Charge good Indoor Filters clean Supply and return plenums are drastically different sizes Indoor board briefly flashed error code but could not repeat House seems to have been a 2 system house previously but had serious renovations done - second platform for outdoor unit in backyard - significantly smaller than current unit - found thermostat wire in small upstairs attic that is not connected to current unit

Dennis C.
Primary electric control. Replaced primary electric control, signed up copper monthly. system is operating at this time.

Casey D.
STU *2 performed. Both systems were operating as intended at the time of inspection and departure. Drains were checked and refrigerant levels were at acceptable levels. Customer stated that one of the condensers sounds loud during startup. Tech recommended a compressor saver and customer was not interested at this time. Customer wished to renew his (Upstairs) contract and upgrade to titanium. Payment was confirmed.