Grandview HVAC, Plumbing & Electrical Services
Since opening our doors in 1962, Comfort Experts has remained committed to serving the members of our community by taking care of their most essential appliances and systems. From upgrading electrical systems to installing new plumbing appliances to repairing HVAC systems, there is no problem too big or too small for our highly trained Grandview technicians to take on.
Reliable Grandview Plumbers
Did you know that the majority of plumbing disasters, such as severely clogged pipes, sewage backflow and sewer line leaks, are preventable? By following just a few of our plumbing protection tips, you can prevent a major plumbing emergency in your home.
Tips To Prevent A Plumbing Emergency:
Never use over-the-counter drain cleaners. Use a mesh drain trap in your shower to keep debris out of your drains. Limit the amount of food waste that goes down your garbage disposal. Only flush toilet paper and human waste down your toilet. Never pour fat, grease or oil down your drains. Schedule professional drain cleaning services at least once a year.
Highly-Qualified Electricians In Grandview
When was the last time your electrical system was inspected by a trained professional? Because much of your electrical system is hidden behind walls, it can be difficult to determine when there is a problem occurring. That’s why routine electrical inspections are so important. Our expert Grandview electricians recommend scheduling an inspection at least once every 3 to 5 years.
Schedule An Electrical Inspection Right Away If:
You're adding on to or remodeling your home. You never have enough outlets. Your electrical bills are consistently high. Your outlets or switches are buzzing. Your bathrooms and kitchen don't have GFCI outlets. You discover frayed or chewed wires. Your home experiences frequent power surges.
Heating Repair & Replacement In Grandview
If your heater isn’t quite working correctly, it can be challenging to determine whether it needs to be repaired or replaced. If your system is young and rarely ever experiences problems, a repair will likely fix the issue. However, if your system is 15 years old or older, your energy bills are through the roof, your system has been repaired multiple times in the last several years or your home is never quite warm enough, it’s time for an upgrade. Luckily, the Grandview furnace repair team at Comfort Experts has access to the highest-performing, most energy-efficient heaters on the market.
Benefits Of A New Heater Include:
Better indoor air quality features. Quieter system operation. Reduced energy consumption. Stronger, more consistent airflow. Lower energy bills. Extended system warranty.
Grandview AC Repair & Replacement
A functioning air conditioner is an absolute must here in Texas. If your system is starting to act up, we recommend having it repaired as soon as possible. Brushing AC problems under the rug can quickly lead to very expensive repairs and even premature system failure.
You Should Schedule AC Repair If:
The unit is blowing weak and/or warm air. Rooms are cooling unevenly. You notice loud banging or rattling noises. The unit turns on and off constantly throughout the day. The evaporator coils are frozen or you notice leaking. There was an unexpected spike in your energy bills. There are burning smells coming your air registers.
Your Comfort Is Our Top Priority
At Comfort Experts, each member of our Grandview team adheres to the highest standards in workmanship, professionalism, and customer care because your comfort matters a great deal to us. You’ll never catch us cutting corners or settling for work that is “good enough." Our team always gets the job done right the first time around. Equipped with state-of-the-art tools and technology, no task is too big or too small for Comfort Experts to take on. No matter how severe the problem may be, Comfort Experts has a solution. Call us 24/7 at 817-341-5149 to schedule your service!
Local Reviews
for Grandview, TX
Our Reviews by City
Excellent Service
Sean - Grandview, TX 76050
Blake was courteous and professional. Did a great job
GrandviewTX76050 32.265-97.17



Excellent service!!!!
Daniel - Grandview, TX 76050
Very efficient and tidy. They explained things thoroughly and answered all our questions!!!!
GrandviewTX76050 32.3325-97.2225



HAD A MINOR ISSUE WITH T-STAT. CAME OUT QUICKLY AND REPAIRED, NO PROBLEM. GREAT SERVICE AS ALWAYS
Larry - Grandview, TX 76050
THANK YOU FOR YOUR ATTENTION AND PERSONAL ATTITUDE TOWARD ALL ISSUES THAT ARISE.
GrandviewTX76050 32.2875-97.305



COMPLETE SYSTEM REPLACEMENT, WORKS QUIET, GREAT !
Larry - Grandview, TX 76050
GrandviewTX76050 32.2875-97.305




AS ALWAYS, COMPLETE, CLEAN, SAFE. COMFORTABLE EXPERIENCE
Larry - Grandview, TX 76050
GrandviewTX76050 32.2875-97.305




great service very well mannered and helpful
Joy - Grandview, TX 76050
Marshal was polite etc and answered a few questions fo me.
GrandviewTX76050 32.2725-97.3



A GENTLEMAN AND DID THE OB LIKE THE OTHERS - THEY ARE ALL GREAT! YOU ARE LUCKY TO HAVE THEM
Joy - Grandview, TX 76050
GrandviewTX76050 32.2725-97.3




great work as i expect that from your company!
Joy - Grandview, TX 76050
This is the first time I was able to get any website of yours on my system. 100% of time, I have been very very pleased with the service and the respect that your employees give me.
GrandviewTX76050 32.2725-97.3



great service
Joy - Grandview, TX 76050
i have been very pleased with the service and the respect all the repair man have showed me.
GrandviewTX76050 32.2725-97.3



Fast service
Sharon - Grandview, TX 76050
Arrived in Scheduled window and out in good time.
GrandviewTX76050 32.2975-97.09



prompt and efficient
Dan - Grandview, TX 76050
Got straight to the task at hand.
GrandviewTX76050 32.3325-97.2225
Response from Comfort Experts Inc.:
Thank you for your review





Brock S.
Found compressor to be grounded out. Will need to order and replace.

Dennis C.
Disconnect was off, turned Disconnect on system is operating normally at this time.

Brock S.
Ran heating tune-up on unit. All amperages tested good, capacitor tested good and heat strips tested within tolerance during heat. Found temperature delta to be low and filter dirty. Also found that UV bulb had not been replaced. Replaced both UV bulb and filter media. Cleaned off outdoor coil and unit was running as normal.

Mike S.
Cap was blown upon arrival and control board locked out on open start circuit replaced 35/5 mfd dual run system is now on and cooling. Refrigerant level is normal. Filter changed.

colby.finch@acgenius.com
service fee

Ryan S.
Saturation temperature is very low at 37 degrees, custo,er stated system was freezing last night before they changed the filter. Coil is still extremely dirty and restricting airflow, recommend pulling and cleaning coil or replacing coil.

Blake B.
Tech arrived at a tuneup. Carrier. The capacitor was within specs. The contactor was in working condition. The condenser coils were clean. The filter was relatively clean. The ductwork, coil and blower area was dirty. There was growth throughout the system. The primary drain was clogged. The customer was informed of recommendations today. He decided to move forward with unclogging and treating the drain system. He will discuss IAQ, Duct and System cleaning with his wife and will call back at a later time. Customer was emailed recommendations. He plans to move soon. The system was functioning upon departure.

Ryan S.
Customer is having serious renovations performed to house and needs all mini split cassettes cleaned, 4 cassettes need new line sets ran with drain lines re routed, condensate pumps installed in inner parts of home, due to the cost and un reliability of mini splits, recommend speaking with engineer about going back with traditional split systems.

Mark W.
2 1/4 turn shot off

Aaron W.
Outdoor unit is operating within specifications, refrigerant levels are slightly low, contactor is burnt and pitted ,indoor unit is operating, evap coil is serverly dirty and rusty,drain line is clogged up,customer purchased coil clean ,drain clean,titanium membership, and contactor, performed all work ,cleaned coat of dirt off coil and found it was eating at coil fins making them weak ,clean coil to best ability without causing further damage

Gavin V.
Came to system with bad capacitor. Replaced capacitors and replaced condenser fan motor.amp draws and capacitor tolerances within range. Cleaned evap coil and condenser coil. Refrigerant levels in range. System cooling efficiently with20 delta. Left system in working order

Mike S.
Insulated 4 wye's, sealed returns, sealed the supply boots in the living room, set the satisfactory rate to 25 min, adjusted the blower settings to profile C and set the furnace to run on 1st stage when on a defrost cycle. Rob will get with

Zak L.
Arrived for service eval Condenser fan motor not coming on Fan motor showing temp of 220 Dual run cap testing out of tolerance on both sides Replaced both with PL warranty Added hard start kit due to high starting amperage Installed pan strip with membership to prevent drain lines from backing up UV system recommended due to biological growth jn the supply plenum

javier.falcon@acgenius.com
Customer wants rec work for next friday

Gavin V.
Replaced faulty capacitor. Replaced dying contactor. System amp draws and capacitor tolerances in range after repairs done. Cleaned outside condenser coil. Inside coil is well. Ducts and blower well. System left in working order

Steven S.
#iaq upon arrival for tune up system on and heating. Inspected outdoor unit. Fan and compressor amp draw within unit specifications. Capacitor within tolerance. Cleaned unit. Refrigerant pressure good. Inspected indoor unit. Growth on blowers and coil. Drain line clear. Em heat functioning. Recommended adding UV system to sterilize bio growth. Left system on and heating.

Gavin V.
Amp draws and capacitor tolerances in range. Cleaned outside coil. Blower and coil are well. electrical connections are sound. System left in working order

Mark W.
Will need bx cable for 2 light and for 2 plug. 6 boxes and seal tight

Mark D.
3/15/23 - Defrost control board is faulty. Can not finish tune up until board is replaced. Low voltage keeps popping fuse in air handler due to faulty board. Need to order board before continuing.

Jhorden P.
Duct cleaning and installation of UV light completed

Dennis C.
Downstairs: run capacitor, primary electrical control, build up on blower wheel, biological growth, evaporator coil rusty and corroded, secondary drain pan rusty, duct cleaning, system upgrade do to age condition and efficiency. Upstairs: secondary drain pan rusty and rusting through, biological growth, system is operating normally at this time. Comfort advisor 3-17-23 10-12.

Dennis C.
Primary electrical control, build up on blower wheel, biological growth, duct cleaning, system upgrade do to age condition and efficiency. Sold lvl2 duct cleaning and uv system to be done 3-15-23.

Wyatt C.
CTU 2008 Goodman Air Handler Treated drain for customer , trap is leaking on drain very small drip notified customer Evaporator coil was acceptable Blower motor and wheel were acceptable UV system was functional Delta T was acceptable 20.1° Electrical connections were acceptable Filter was acceptable 2010 Amana Heat Pump Dual Capacitor was out of manufacturer range on fan side Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Electrical connections were acceptable Washed the unit from inside out Waxed the top of the unit Cleaned debris out of unit Fixed the leaky drain trap , installed new 40/5 capacitor and installed drain pan treatment

riley.hobson@acgenius.com
Went to house for htu on one system. Checked indoor first. Blower is clean, filter is clean, electrical connections are secure, evap coil is fine, Heating strip operational. Recommended drain switch, customer declined. Went to outdoor and checked unit. Capacitor in tolerance, fan Amp normal, compressor amps normal, compressor savor operational. Recommended whole home surge protection to protect appliances, customer said no. Defrost board looks good, coil is clean. Recommended generator, customer has one. Unit is operational.

Robert G.
Replaced inducer motor under warranty