Plus you can count on getting a Certified AC Genius, Plumbing Genius, or Electrical Genius. Which means we don’t use “salesmen in disguise” or “selling techs,” like other home service companies. Instead we have our own training center to ensure you always get the honest expertise required to repair your problem right, right then and there.

I hope that fixes the problem with the heat pump I have only had the unit put in 39 days ago
Noticeable difference in airflow from one side to the other
On 7/27/26, I conducted a thorough diagnostic on a generator experiencing charging issues. The charging circuit neutral was found to be improperly bonded to the generator's negative ground circuit on the transfer switch control module. I carefully removed this connection. Although the battery was charged at 13.04 VDC, the terminals were heavily corroded. I cleaned the terminals and applied a protective coating. Upon restarting the generator, it initially reached normal RPM but exhibited an engine miss. Subsequent attempts to restart the generator were unsuccessful, with the engine struggling to reach RPM and displaying a low fuel pressure code. Pressure tests confirmed normal fuel pressure up to the injection system, but the fuel butterfly remained closed during starting attempts, indicating a potential issue with the fuel injector or carburetor. I will verify parts availability and return to complete the repair.
4/21/2026 Brian H – Evaluated generator starting attempts after homeowner replaced starter. Found battery voltage dropping to 9.6 VDC during starting attempts. Battery terminals are clean and tight. The generator batteries are failing at an unacceptably high rate of 1 or more per year. This has been happening since the unit was installed. Will relay information to manufacturer to see what needs to happen next and if they are willing to do anything to help with the problem.
Diagnosed generator starter (0G7461RWK) has failed. Solenoid is receiving signal to start but starter motor will not turn. According to Generac parts help line, it will also need a spacer kit (0G0860). Recommend starter replacement.
Super tune up performed today on an Amana heat pump with air handler installed in 2023. All electrical connections are tight with no corrosion. Blower wheel and evaporator coil are clean. All amp draws are within spec. Refrigerant levels are in range. Outdoor unit was washed and waxed. Suggest adding surge protection to the main panel.
Performed super tune on trane heat pump system. Checked all electrical connections indoor and changed customer supplied filters. All connections are tight and have no burn marks. Drain line is clear. Informed customer about compressor saver and iaq products.
Generator is not the problem it's the septic making nose