Plus you can count on getting a Certified AC Genius, Plumbing Genius, or Electrical Genius. Which means we don’t use “salesmen in disguise” or “selling techs,” like other home service companies. Instead we have our own training center to ensure you always get the honest expertise required to repair your problem right, right then and there.
Kellen was very professional and completed the work in a timely manner. He also was sure to wear shoe covers inside the house.
Very Professional Mr. Alec
Efficiency, knowledge, friendliness, perfect explanation of service.
Found compressor saver bad replaced and unit came on. Fan is going out on thermal overload recommend replacing fan and then gave option for new system customer declined both
Completed tune up on system. Checked both indoor and outdoor unit checked all electrical
Oh oh oh our
2006 5t attic horizontal hp. System down upon arrival. Frozen coils on the intake side. Refrigerant leak detection underside. Heavy rust throughout indoor unit. Refrigerant charge below manufacturer tolerance. I shared with homeowner all pertinent information and discussed age, performance, saftey and parts availability. Homeowner agreed to a CA appointment 5/26/25 @10a. System down. Slight language barrier. If possible, provide window units. I've informed homeowner the best I can that if he were to purchase window units then we would buy them back upon install. But I'm not sure he understood.
2006 5t attic horizontal hp. System down upon arrival. Frozen coils on the intake side. Refrigerant leak detection underside. Heavy rust throughout indoor unit. Refrigerant charge below manufacturer tolerance. I shared with homeowner all pertinent information and discussed age, performance, saftey and parts availability. Homeowner agreed to a CA appointment 5/26/25 @10a. System down. Slight language barrier. If possible, provide window units. I've informed homeowner the best I can that if he were to purchase window units then we would buy them back upon install. But I'm not sure he understood.
2006 5t attic horizontal hp. System down upon arrival. Frozen coils on the intake side. Refrigerant leak detection underside. Heavy rust throughout indoor unit. Refrigerant charge below manufacturer tolerance. I shared with homeowner all pertinent information and discussed age, performance, saftey and parts availability. Homeowner agreed to a CA appointment 5/26/25 @10a. System down. Slight language barrier. If possible, provide window units. I've informed homeowner the best I can that if he were to purchase window units then we would buy them back upon install. But I'm not sure he understood.
2006 5t attic horizontal hp. System down upon arrival. Frozen coils on the intake side. Refrigerant leak detection underside. Heavy rust throughout indoor unit. Refrigerant charge below manufacturer tolerance. I shared with homeowner all pertinent information and discussed age, performance, saftey and parts availability. Homeowner agreed to a CA appointment 5/26/25 @10a. System down. Slight language barrier. If possible, provide window units. I've informed homeowner the best I can that if he were to purchase window units then we would buy them back upon install. But I'm not sure he understood.
Electrical inspection. Emailed estimate to add 2 exterior outlets. And surge protection. Repaired kitchen outlet. And installed gfci. New member.
Quoted a level 1 36k straight cool closet upflow wall mount for $9,000
Homeowner is a flipper, currently resides in home though. Indoor is goodman 2009 and outdoor is carrier 2022. Expired manufacturers warranty. Evaporator coil is heavily blocked and leaking detectable refrigerant. Coil has a history of freezing. Blower wheel has extreme buildup and heavy biological growth. Filter system is poor. Condenser unit is not level. Refrigerant levels are low. Inrush amperage on compressor exceeds manufacturers tolerance. Contactor is buzzing. Homeowner wants condenser unit moved around the corner. As I uncovered all the issues, decided to talk to a CA 4/5/25 @10am. Homeowner needed information to give to his insurance company of the year of both systems so I made an estimate with that information and emailed it. I also encouraged him to not deliver the information to insurance company if he infact replaces the system. System is functional but heavily diminishing in performance.
Homeowner is a flipper, currently resides in home though. Indoor is goodman 2009 and outdoor is carrier 2022. Expired manufacturers warranty. Evaporator coil is heavily blocked and leaking detectable refrigerant. Coil has a history of freezing. Blower wheel has extreme buildup and heavy biological growth. Filter system is poor. Condenser unit is not level. Refrigerant levels are low. Inrush amperage on compressor exceeds manufacturers tolerance. Contactor is buzzing. Homeowner wants condenser unit moved around the corner. As I uncovered all the issues, decided to talk to a CA 4/5/25 @10am. Homeowner needed information to give to his insurance company of the year of both systems so I made an estimate with that information and emailed it. I also encouraged him to not deliver the information to insurance company if he infact replaces the system. System is functional but heavily diminishing in performance.
Homeowner is a flipper, currently resides in home though. Indoor is goodman 2009 and outdoor is carrier 2022. Expired manufacturers warranty. Evaporator coil is heavily blocked and leaking detectable refrigerant. Coil has a history of freezing. Blower wheel has extreme buildup and heavy biological growth. Filter system is poor. Condenser unit is not level. Refrigerant levels are low. Inrush amperage on compressor exceeds manufacturers tolerance. Contactor is buzzing. Homeowner wants condenser unit moved around the corner. As I uncovered all the issues, decided to talk to a CA 4/5/25 @10am. Homeowner needed information to give to his insurance company of the year of both systems so I made an estimate with that information and emailed it. I also encouraged him to not deliver the information to insurance company if he infact replaces the system. System is functional but heavily diminishing in performance.
Homeowner is a flipper, currently resides in home though. Indoor is goodman 2009 and outdoor is carrier 2022. Expired manufacturers warranty. Evaporator coil is heavily blocked and leaking detectable refrigerant. Coil has a history of freezing. Blower wheel has extreme buildup and heavy biological growth. Filter system is poor. Condenser unit is not level. Refrigerant levels are low. Inrush amperage on compressor exceeds manufacturers tolerance. Contactor is buzzing. Homeowner wants condenser unit moved around the corner. As I uncovered all the issues, decided to talk to a CA 4/5/25 @10am. Homeowner needed information to give to his insurance company of the year of both systems so I made an estimate with that information and emailed it. I also encouraged him to not deliver the information to insurance company if he infact replaces the system. System is functional but heavily diminishing in performance.
Repair on you HVAC unit
Tech talked to home owner 5amp fuse kept blowing as soon as it was installed tech tried and the transformer popped. Tech installed a new transformer and unit was working perfectly fine tech made sure everything was running properly
2020 Goodman airhandler Checked and tightened all electrical connections Heatstrips were functional and within manufacture range Customer recently changed filters Drain has heavy build up in trap Blower motor and wheel were acceptable Blower cap was within manufacture range Evaporator coil was acceptable 2020 Goodman straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended clearing and treating drain, also recommended compressor saver Customer declined all Recommendations. Not responsible for any damage that may occur
Arrived for service Eval Dual run cap failed Replaced and added a hard start kit because compressor was exceeding LRA Installed IAQ200 UVC air flow cleaner due to biological growth in the air handler Installed drain switch to prevent water damage due to drain blockage