Plus you can count on getting a Certified AC Genius, Plumbing Genius, or Electrical Genius. Which means we don’t use “salesmen in disguise” or “selling techs,” like other home service companies. Instead we have our own training center to ensure you always get the honest expertise required to repair your problem right, right then and there.
Derek did good. Thanks Derek
Courteous and knowledgeable
Heatpump had E37 code (faulty control board) fix is replacement. Customer stated he will talk with manufacture
Customer wanted estimate for replacing old rinnai tankless water with new navien unit.
I have looked at the gfcis causing some issues the one in the kitchen had just tripped the breaker so I turned that one back on and the one outside wasn't showing any signs of degration and was only a few month old
Upon arrival system was off, turned system on and outdoor came on but indoor would not. During evaluation reset breakers and started system, blower came on and off as should multiple times. Checked components on Heatpump and found auxiliary motor starter had failed also found disconnect was broken. Recommended replacement of safety disconnect and auxiliary motor starter. Customer declined safety disconnect but wanted to replace auxiliary motor starter. Left system in heat mode
Called out for leaking hosebib. Sweat off old valve, solder on copper mip adapter and install new silcock. Set up on membership
11/27/24 Installed new gas service and repiped 4 drops. All new plumbing held test. Turned gas on and lit all pilots and tested furnace. Customer has heat and hot water for the holiday. Will need to go back on Friday to button up a few minor details. Will also need to schedule an electrician to bond the system
We will cut out bad pipe and fittings and replace. After repair, pressure test is still showing a leak. I am not able to turn gas back on at this time. Estimates given for new service line and 4 drop repipe. This job is financed We will Trench from meter to corner of home. After excavation we will install new 1"poly gas service with stop and union at house and run new csst gas lines to all gas appliances with new stops and supplies. New gas system will be bonded electrically as per code. All new work will be tested and installed as per code
Customer requests a plumber to come out to perform a pressure test on the gas line. Heating tune up performed today on an Amana gas furnace with straight cool condenser. PSC blower motor and capacitor are acceptable. Blower wheel and evaporator coil are slightly dirty. Attic is very low on insulation. Furnace safeties and functions are working properly. Technician smelled the odor of gas outside by the condenser. Technician turned off the furnace and the gas water heater pilot and watched the meter to determine there is a slow leak somewhere in the system. Requesting a plumber to come out and perform a pressure test on the gas line. Gas was turned off at the meter before departure.
When the indoor control board was replaced it was connected incorrectly on the low voltage causing the air conditioner to come one every time the blower would come on. Corrected the issue and performed function check. System is operating properly in air conditioning, heating, and fan. Recall on me.
Changed out furnace control board. While performing a function check found the PSC blower motor to be overheating and over amping. Replaced 1/2hp, 115v, 1075rpm blower motor and 10mfd capacitor under warranty. System running in cool upon departure.
While system is running the blower will turn off and on intermittently. Losing high voltage power coming out of the control board. Ordering a new control board under P&L warranty.
Valve was off in attic not allowing flow to master bath sinks and shower. On hot side only turned valve on to return flow to bath
Replaced all lines around the water leak with new fittings, insured no leaks and installed laundry sink p-trap
Toilet and kitchen faucet was low pressure due to break on main line flooding system with debris Install new angle stop under kitchen sink and cleared kitchen faucet cartridge of debris No warranty on cartridge clearing. Recommend new cartridge for full pressure Installed new fill valve and supply line in hall bath
10/3. Work completed. Please send N. BURKE if any future electrical work needs done. Thank you. Plumbing lead set to run this afternoon.
PLEASE SCHEDULE WORK FOR THURSDAY 10/3 FIRST APPOINTMENT. BE ALL DAY. 7 bubble covers. 1 2 gangcbubble cover. 8 WP gfcis. 1 wp receptacle. 50' 3/4" pvc. 2 3/4 LBs. 3 90s. Straps. 2 gang bell box with 3/4 kos. Homeline 120. Roll of 12-2. 2- 1/2 inch minis. Customer 2404.70.
Quoted a level 1 through 5 60k gas horizontal for $10,370 – $27,288 Gave 5% discount on levels 1 and 2. Gave 10% discount on levels 3, 4 and 5 Also Quoted a ultra high efficiency filtration system with UV light for $2,365
Hammer arrestors installed and checked to insure lines quit bouncing Changed shut off valve, insured no leaks. Water is on and no leaks
9/18/24 Returning in the morning to complete work
2007 5t gas r22 trane attic horizontal. Called for water damage concerns, history of drain line issues. Greetings, introductions and expectations while homeowner gave actour around the home and a History of the issues. Two thermostats were on the counter, one was dropped by homeowner and I popped the plastic case back into place and noticed corrosion at the battery terminals. I removed batteries and set both tstats back in place (common wire allows power). I explained this to homeowner. Homeowner brought me to the laundry room and closet where the water damage was present. I utilized my infared camera to further investigate. Homeowner lptold me her son-in-law owns a company and I asked to speak to him on the phone. While on the phone, Les (son-in-law) told me he knows what the issue was and that he'll be here in Wednesday to fix all the issues and hopes I can get them back up and running. My inspection discovered- Filter needs replacement. The main condesate drain line was s
Quote
Replaced low pressure switch inside of the heat pump. Replaced filter drier in the liquid line and pressure tested the system at 300psi to check for leaks. Pulled vacuum to 500 microns and released the refrigerant back into the system. Both systems are running normally at this time.