HVAC, Plumbing, & Electrical Services
Simple Answer: We always answer the phone, and come when you call to fix what needs fixed — and we stand behind our word and our work.
Plus you can count on getting a Certified AC Genius, Plumbing Genius, or Electrical Genius. Which means we don’t use “salesmen in disguise” or “selling techs,” like other home service companies. Instead we have our own training center to ensure you always get the honest expertise required to repair your problem right, right then and there.
Comfort Experts is proud to serve Poolville, TX, and the surrounding areas with quality, comprehensive HVAC services. Since 1962, we’ve helped local homeowners take their indoor comfort to the next level. Whether you need installation, replacement, maintenance or repair, we’ve got you covered – 24/7! We offer a wide range of services, including AC, heating, plumbing, electrical and solar energy. We’re proud to offer a free second opinion so you know you’re always getting a fair deal. With Comfort Experts, you’ll never have to compromise on comfort. We know the ins and outs of heating, cooling and more so you don’t have to.
See what your Poolville, TX, neighbors are saying about our exceptional service. We’re here for you day and night, so when you need HVAC care you can trust, give us a call at (817) 341-5149!
Great service and professionalism. I didn’t feel pressured to make a decision or to lean one way or the other.
Mark was great. Excellent service, very thorough. Would highly recommend!
Justin was knowledgeable and answered all of my questions.
Great service.
Adam was very informative. He answered all my questions gave me a price on a new unit and I just can't see spending that much money for a water filter but thanks for sending him out
Very nice young man. Polite and informative.
Joe and Angel were thorough in the install, answered all my questions, and addressed all my concerns. Toby was a great source of information, and his customer/communication skills were a huge factor in sealing the deal.
Great service! Ian was very knowledgeable and knew right away what our issue would be. He was correct, and got repairs in place quickly. Service took less than 45 minutes!
Justin with Hobson A/C was very professional and thorough. I am 66 years old and Justin was the best tech I have ever encountered.
Cody was very thorough, informative and polite. Its great to see someone good at their job.
Ian and the team was great! They came in diagnosed the problem and replaced that water heater.
Mark is a professional who knows his work and doesn’t mind explaining what we don’t understand
Very helpful and knowledgeable on looking at our unit at 10pm on a Monday!!
Hobson AC/Comfort Experts service exceeded my expectations and believe me with Hobson being my last name we are our biggest critics. Brian, Brady, Joe, Jose, Daniel and Jonathan all showed up and within 3 hours had the new Generac generator set, hooked up and professionally installed. I could not be any more pleased. I’m not looking forward to another electricity outage but if we have one we are a little better prepared. Thank you gentlemen on a job well done. Mr. & Mrs. Hobson Peaster, TX.
Shiwed uo on time and git the jib done
The technician was very helpful and explained everything and told me what I needed to do the next time it happened
Great job guys. Think about this who needs their AC fixed on December 27th. We did. Great job.
He was very professional and told me options that I might have to do
The three men that came out did such a great job I was so amazed how will they did considering the conditions they were working with in such Heat I feel so bad for them but overall I couldn't have asked for a better crew
everyone is so nice weather its the office or worker
2022 Carrier Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Drain has no drain safety Heat kit is functional and within manufacture range Blower Motor and wheel were acceptable Evaporator coil was acceptable Condensate pan has biological growth build up 2022 Carrier Heatpump Checked and tightened all electrical connections Dual run cap is below tolerance (weak) Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Repairs drain switch and dual run cap Recommendations micro air soft start kit or compressor saver along with UV system and HBPPLAN
Performes tune up on both master bed and main house systems Bosch inverter main and master Checked and tightened all electrical connections Filters are in need of changing Drains were clear and draining at this time Blower motors and wheels were acceptable Blower Caps were within manufacture range Evaporator coils were acceptable Primary electrical boards on inverter Heatpumps were acceptable Refrigerant levels were acceptable at this time Fan blades and motors were acceptable Condenser coils were acceptable Cleared debris from the bottom of the systems Washed condenser coils from the inside out Waxed the top of both units Recommended HBPPLAN and UV systems
Customer changed the UV bulb himself. Technician arrived to find that the breakers on the air handler were off. Switched breakers to on and performed function check n system running normally at time of departure.
Super tune up performed today on an Amana heat pump with air handler installed in 2021. All electrical connections are tight with no corrosion. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Attic is low on insulation. Highly suggest adding insulation to the attic to help with the efficiency of the home. Outdoor unit was washed and waxed.
Performed super tune up on a 2022 armana heat pump. Indoor unit had filter dirty and swapped out with new filter customer gave us, blower motor acceptable, evaporator coil was clean, all electrical components were tightened and pulling proper amperage. Outside unit was washed and waxed clean, all pressure readings on gauges were acceptable, all electrical components were pulling proper amperage. Recommended customer iq300, micro air soft start, condisate pan treatment and installed everything on her system, at departure system was functioning properly.
1/28/26 Techs to return with Mark W Friday after meeting 1/30/26 Technician found that the thermal limit switch is the cause for two heat strips not to turn on technician is ordering a new one Technician will collect payment when technician returns
Both breakers to air handler were overheating at the bus bar attachment. Replaced both Eaton breakers (60 amp x 2), relocated them in the panel, and system is functioning normally at this time. Buss bar has discoloration where breakers were attached. I recommend buss bar replacement or breaker panel replacement to ensure proper operation and safety.
I uv
Mark D. performed a thorough annual heating system check, cleaning filters, inspecting ductwork, and ensuring all components functioned properly. Safety and efficiency were prioritized throughout the maintenance.
Heating tune up performed today on a down flow air handler with heat pump installed in 2019. All electrical connections are tight with no corrosion. Blower motor is acceptable. Blower wheel and evaporator coil are clean. Mild corrosion is present on the evaporator coil. Compressor and condenser fan motor are working as they should. Reversing valve and defrost control board are acceptable. Heat strips are pulling proper amperage. Outdoor unit was washed and waxed.
1/2/26 Reworked estimate will have concrete removal crew demo first then begin rec work …will return Monday second call for remainder of rec work Will return with Daniel Monday morning
Elc is good and customer doesn't need me
Arrived to no heat on Daiken mini split 3 head system. System shutting down on low pressure. Found leak in evaporator coil in bedroom unit. Presented customer with estimates to repair.
Service performed today on four generac air cooled generators. Main house unit- air filter, spark plugs and oil and oil filter were changed. Checked valve clearance to find all within spec. Battery checks as good. Reset maintenance schedule and performed function check. System operating normally. Barn unit- air filter, spark plugs and oil and oil filter were changed. Checked valve clearance to find all within spec. Battery checks as good. Reset maintenance schedule and performed function check. System operating normally. Guest house/ lodging- two stand by generators at this location. air filter, spark plugs and oil and oil filter were changed. Checked valve clearance to find all within spec. Battery checks as good. Reset maintenance schedule and performed function check. System operating normally. All systems are performing normally at this time. All systems were cleaned externally and inside of the casings. All batteries check as good. Barn unit showed evidence of a possible
Her panels looked great she does not have surge protection but she's about to sell the house and would like to hold off, gfci's are present and in the correct locations the only issues she has are brown outs
Arrived to no heat. Found that the primary electrical control had failed and was not passing high voltage through the contacts. Replaced electrical control and added a compressor saver to help with the efficiency and reliability of the system upon start up. Performed function check. System running and heating the home upon departure.
Super tune up performed this evening. Two year old Trane heat pump with air handler. All electrical connections are tight with no corrosion. X13 blower motor is acceptable. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed. Customer has signed up for the military appreciation membership.
Electrical to HVAC He's concerned with his compressor, says it keeps coming on without performing any function so no air is blowing and then shuts off again
2023 American Standard Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Blower motor and wheel were Evaporator coil was acceptable Condensate pan has slight biological growth build up Supply plenum was acceptable 2023 American Standard Straight Cool Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Recommended UV system to keep Airhandler and air quality clean and compressor saver as compressor is over LRA limit. Signed up for HBPPLAN
2021 Lennox Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Blower motor and wheel were acceptable Evaporator coil was acceptable Heatstrips were functional and within manufacture range 2021 Lennox Heatpump Checked and tightened all electrical connections Dual Run cap is right at manufacture tolerance Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed top of the unit Recommended HBPPLAN, UV 300 or 200, dual run cap and compressor saver
Upon arrival system was flat. Added nitrogen to the system And leak detector picked up on trace amounts of 410 in the same location of the previous company. Gave pricing on parts and customer stated he's going to wait and weigh out options
2022 Amana Airhandler Checked and tightened all electrical connections Drain has slight build up but is still draining Changed customer provided filter Blower motor and wheel were acceptable Evaporator coil was acceptable UV system is functional UV lamp is out and needs replacement 2022 Amana Heatpump Checked and tightened all electrical connections Dual Run cap was within manufacture range Primary electrical unit was acceptable Compressor saver is functional Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from inside out Waxed the top of the unit Recommended lamp replacement or UV system upgrade Replaced UV lamp today
.
Level 5 24k whole home automatic generator $21,000