Rowlett TX
Rowlett AC & Heating Services
The purpose of your heating, air conditioning and ventilation system is to provide a comfortable and safe environment inside your home. This could be anything from keeping your home heated or cooled at your preferred temperature to improving the indoor air quality and circulation of your home to help fight against respiratory and other illnesses. Can you guarantee that your unit is running at its full potential and successfully providing the ideal comfort and safety for your Rowlett home? If you answer “no” to this question it is time to have your unit inspected. Call us today at 817-341-5149 to schedule your inspection!
Rowlett AC Repair & Replacement
If your unit is unable to be repaired and has to be replaced, we’re here to quickly get a new unit put in so you can get back to the comfort you deserve. All you have to do is choose a new system! We provide a wide range of HVAC units to choose from so we know that you will be able to find a new system that caters to your needs.
Our 5-star online reviews show that we are dedicated to customer satisfaction. We have made it our goal to leave you saying that you had a good experience with our company. We take pride in the work we do and always back our work with a 100% customer satisfaction guarantee. You will always be left satisfied and we will always leave knowing we have successfully assisted your family with your Rowlett AC repair needs.
Here For All Your HVAC Needs
Comfort Experts, Inc. has made it our mission to keep Rowlett families comfortable all year long and assure that your home is a safe environment. No matter the issue with your heating and cooling systems, we’re here to help. By offering AC inspection and repair, we can diagnose a malfunction quickly and fix the problem, returning your system to peak performance.
In addition to heating and cooling, we specialize in plumbing and electrical services so you don’t have to worry about hunting down multiple contractors. We take care of all your HVAC systems from start to finish. For the most comfortable call you’ll ever make, we’ll be here 24/7 at 817-341-5149 !
Recent Jobs and Reviews in Rowlett, TX
Our Local Reviews by City
- Addison, TX (3)
- Aledo, TX (137)
- Allen, TX (17)
- Alvarado, TX (48)
- Annetta, TX (1)
- Annetta North, TX (1)
- Argyle, TX (28)
- Arlington, TX (474)
- Aubrey, TX (10)
- Aurora, TX (1)
- Azle, TX (94)
- Balch Springs, TX (2)
- Bedford, TX (50)
- Benbrook, TX (123)
- Bluff Dale, TX (3)
- Bowie, TX (2)
- Boyd, TX (20)
- Bridgeport, TX (6)
- Brock, TX (4)
- Burleson, TX (222)
- Carrollton, TX (41)
- Cedar Hill, TX (40)
- Chico, TX (1)
- Cleburne, TX (202)
- Colleyville, TX (23)
- Cool, TX (2)
- Coppell, TX (13)
- Corinth, TX (17)
- Cresson, TX (13)
- Cross Roads, TX (3)
- Cross Timber, TX (1)
- Crowley, TX (93)
- Dallas, TX (102)
- Decatur, TX (9)
- DeCordova, TX (2)
- Denton, TX (78)
- DeSoto, TX (16)
- Duncanville, TX (3)
- Edgecliff Village, TX (2)
- Ennis, TX (2)
- Euless, TX (62)
- Everman, TX (7)
- Fairview, TX (4)
- Farmers Branch, TX (10)
- Flower Mound, TX (36)
- Forest Hill, TX (13)
- Fort Worth, TX (1781)
- Frisco, TX (37)
- Garland, TX (20)
- Glen Rose, TX (29)
- Glenn Heights, TX (1)
- Godley, TX (21)
- Gordon, TX (15)
- Graford, TX (10)
- Granbury, TX (408)
- Grand Prairie, TX (106)
- Grandview, TX (12)
- Grapevine, TX (29)
- Haltom City, TX (37)
- Haslet, TX (66)
- Hickory Creek, TX (1)
- Highland Village, TX (19)
- Hudson Oaks, TX (58)
- Hurst, TX (44)
- Irving, TX (53)
- Itasca, TX (1)
- Jacksboro, TX (3)
- Joshua, TX (67)
- Justin, TX (18)
- Keene, TX (8)
- Keller, TX (51)
- Kennedale, TX (38)
- Krugerville, TX (4)
- Krum, TX (2)
- Lake Dallas, TX (2)
- Lake Worth, TX (6)
- Lakeside, TX (8)
- Lancaster, TX (1)
- Lantana, TX (7)
- Lewisville, TX (49)
- Lillian, TX (3)
- Lipan, TX (30)
- Little Elm, TX (17)
- Mansfield, TX (191)
- McKinney, TX (29)
- Mesquite, TX (5)
- Midlothian, TX (22)
- Millsap, TX (60)
- Mineral Wells, TX (84)
- Newark, TX (4)
- North Richland Hills, TX (49)
- Northlake, TX (7)
- Oak Point, TX (5)
- Odessa, TX (1)
- Palo Pinto, TX (6)
- Paradise, TX (10)
- Perrin, TX (9)
- Plano, TX (44)
- Ponder, TX (4)
- Poolville, TX (20)
- Prosper, TX (8)
- Providence Village, TX (2)
- Rainbow, TX (3)
- Raleigh, NC (1)
- Red Oak, TX (7)
- Rhome, TX (12)
- Richardson, TX (44)
- Richland Hills, TX (16)
- Rio Vista, TX (6)
- River Oaks, TX (7)
- Roanoke, TX (18)
- Rockwall, TX (1)
- Rowlett, TX (11)
- Royse City, TX (3)
- Runaway Bay, TX (3)
- Saginaw, TX (77)
- Sanger, TX (4)
- Santo, TX (6)
- Shady Shores, TX (4)
- Southlake, TX (24)
- Springtown, TX (128)
- Strawn, TX (7)
- The Colony, TX (14)
- Tolar, TX (12)
- Trophy Club, TX (18)
- Venus, TX (27)
- Watauga, TX (33)
- Waxahachie, TX (11)
- Weatherford, Texas (1)
- Weatherford, TX (683)
- Westlake, TX (2)
- Westworth Village, TX (10)
- White Settlement, TX (26)
- Willow Park, TX (49)
- Wylie, TX (2)
Reviews
Job Locations
On this job I inspected the gas furnace and found everything in tolerance. I did find a bad uv bulb. Today they have decided to upgrade to the iaq200. Heat differential is 30 system has a new filter and is ready for heating season.
Arrived for HTU All components were working and intolerance Recommmend UV Bulb Customer wants to buy his own 24v uV bulb
For this evaluation I showed up to the customer's house and the downstairs unit was not running. Inside there was a call for cool, but only hot air was being blown. There was no sound coming from the condenser to indicate the capacitor was out, which I did test and it was still within tolerance. However there was not high voltage at the contactor and the breaker was tripped at the disconnect. I unplugged the compressor and turned the system back on and the fan ran and did not trip the breaker, indicating the compressor is grounded. Customer stated after the storms in May, that's when she started to notice that her AC was not running as efficiently. My phone the customer that this is because the compressor is basically fried and that is the heart of the system and there's no refrigerant being pumped to cool the house.
For the schooling tonight I expected the furnace and condenser, all equipment was measuring with a manufacturer's specs and running well. Due to the condenser being 5 years old I recommended a compressor saver to lower the amp draw at in Rush and the customer decided to go with that as well as a pan strip as her drain line was starting to be slow with training. At your installing the compressor saver the inrush went down by approximately 30%.
No show
During inspection discovered that drain line was clogged and was tripping the drain switch Got drain line cleared and found the clog was in the bathroom p trap Left customers house with system operating properly
Tech arrived at a membership tune-up. Upon inspection, the capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The surge protector was functioning. The filter was dirty and replaced. The drain was clear and bleach was poured. The UV system was functioning. The Delta and refrigerant was within range. The customer was informed of recommendations today. We will wait until the next trip to upgrade the UV system when the current bulb is expired. The system was functioning upon departure.
Tech arrived at a membership tune-up. Upon inspection, the blower capacitor was out of tolerance. The there was an outdated box filter installed. The Delta and refrigerant was out of range. The drain was clear and bleach was poured. The heating system reached complete ignition. The UV system was not functioning. The customer was informed of recommendations today. She decided to move forward with replacing the capacitor and adjusting the refrigerant. These tasks were performed and tested. The system was functioning upon departure. She will consider other recommendations and call back in at a later date.
Tech arrived at a warranty tuneup. Upon inspection the capacitor was within specs. The outside system was functioning. The filter was dirty and replaced. The ductwork and blower area was dirty. The system had growth throughout. The Delta was within range. The condenser coils were hosed off to assist with air flow across the coils. The customer was informed of recommendations today. She will speak to her husband about ductwork and the IAQ 200 System and Air Cleaner. The system was functioning upon departure.
Mike R. completed a duct cleaning quote.
During inspection verified that system was working properly Spoke to customers about recommendations for the system to help prevent buildup and extend the life of the system and customers wanted to have some time to talk it over before committing to anything and said they would call us if they decided to move forward with any recommendations
System could benifit from level duct cleaning and auv system. All this is in my estimates. She needs to talk to husband before any decisions can be made.
Tech arrived at a membership tune-up. Upon inspection, the capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The Delta and refrigerant was within range. The filter was dirty and replaced. The drain was clear and bleach was poured. The customer was informed of recommendations today. He decided to move forward with upgrading the box filter to an AprilAire filter. The filter kit was installed and the new filter was installed. The customer was given reorder information. The system was functioning upon departure.
Tyler L completed electrical tune-up opened up the panel tightened connections had a surge protector as well everything was good inside of the panel there was an open low voltage box outside as well we put a plug cover on a plug in the living room we replaced a plug in the living room as well and replaced a outlet in a bathroom with a GFCI
Tech arrived at a 45. Upon inspection, the system was not cooling. The outside disconnect was checked and was in the Office position. The breaker was repositioned and the system regained functionality. The system was cooling upon departure.
Tech arrived at a membership tune-up. Upon inspection, the duel run capacitor was within specs. The contactor had minor scorching. The filter was dirty and replaced. The drain was clear and bleach was poured. The UVC system was switch to run continuously. The basic UV bulb was out. The heating system reached complete ignition. The inducer motor was pulling close to max amps. The customer was informed of recommendations today. He decided to move forward with replacing the basic UV bulb. This item was replaced and functioning. The system was functioning upon departure.
Tech arrived at a warranty tuneup. Upon inspection the capacitor was within specs. The contactor was in working condition. The surge protector was functioning. The Delta was within range. The Filter was dirty and replaced. The drain was clear and bleach was poured. The UV bulb was not functioning. The customer was informed of recommendations today. He decided to move forward with replacing the existing UV bulb. The bulb was replaced, tested, and working. The system was functioning upon departure.
On arrival both systems were running and cooling. Both indoor units had clear drain lines, clean coils and clean blowers. The outdoor units were both in good shape after cleaning and passed all electrical tests. I recommended a compressor saver kit for the newer unit and with the customers permission i installed it. As I left I ensured that both systems were running and cooling. Thanks for choosing comfort experts and have a great day!
Tech arrived at a membership service call. The customer mentioned that she was having thermostat problems. The thermostat was not functioning at this time. The customer recently replaced the batteries and they were in backwards. After repositioning, the thermostat began functioning. The drain system was checked and was found to be clogged. The trap was disassembled at the sink. Everything from the sink trap up was cleared. The trap was fastened and there were no leaks observed. The sink was tested and was draining slowly. Chemical was introduced and helped the flow. The customer was informed that if this happens again, a plumber should be called as the AC plumbing should be clear. A treatment strip was added to help keep the drain system clean. The system was functioning upon departure.