HVAC, Plumbing, & Electrical Services
Simple Answer: We always answer the phone, and come when you call to fix what needs fixed — and we stand behind our word and our work.
Plus you can count on getting a Certified AC Genius, Plumbing Genius, or Electrical Genius. Which means we don’t use “salesmen in disguise” or “selling techs,” like other home service companies. Instead we have our own training center to ensure you always get the honest expertise required to repair your problem right, right then and there.
Comfort Experts is proud to serve Poolville, TX, and the surrounding areas with quality, comprehensive HVAC services. Since 1962, we’ve helped local homeowners take their indoor comfort to the next level. Whether you need installation, replacement, maintenance or repair, we’ve got you covered – 24/7! We offer a wide range of services, including AC, heating, plumbing, electrical and solar energy. We’re proud to offer a free second opinion so you know you’re always getting a fair deal. With Comfort Experts, you’ll never have to compromise on comfort. We know the ins and outs of heating, cooling and more so you don’t have to.
See what your Poolville, TX, neighbors are saying about our exceptional service. We’re here for you day and night, so when you need HVAC care you can trust, give us a call at (817) 341-5149!
Mark was great. Excellent service, very thorough. Would highly recommend!
Justin was knowledgeable and answered all of my questions.
Great service.
Adam was very informative. He answered all my questions gave me a price on a new unit and I just can't see spending that much money for a water filter but thanks for sending him out
Very nice young man. Polite and informative.
Joe and Angel were thorough in the install, answered all my questions, and addressed all my concerns. Toby was a great source of information, and his customer/communication skills were a huge factor in sealing the deal.
Great service! Ian was very knowledgeable and knew right away what our issue would be. He was correct, and got repairs in place quickly. Service took less than 45 minutes!
Justin with Hobson A/C was very professional and thorough. I am 66 years old and Justin was the best tech I have ever encountered.
Cody was very thorough, informative and polite. Its great to see someone good at their job.
Ian and the team was great! They came in diagnosed the problem and replaced that water heater.
Mark is a professional who knows his work and doesn’t mind explaining what we don’t understand
Very helpful and knowledgeable on looking at our unit at 10pm on a Monday!!
Hobson AC/Comfort Experts service exceeded my expectations and believe me with Hobson being my last name we are our biggest critics. Brian, Brady, Joe, Jose, Daniel and Jonathan all showed up and within 3 hours had the new Generac generator set, hooked up and professionally installed. I could not be any more pleased. I’m not looking forward to another electricity outage but if we have one we are a little better prepared. Thank you gentlemen on a job well done. Mr. & Mrs. Hobson Peaster, TX.
Shiwed uo on time and git the jib done
The technician was very helpful and explained everything and told me what I needed to do the next time it happened
Great job guys. Think about this who needs their AC fixed on December 27th. We did. Great job.
He was very professional and told me options that I might have to do
The three men that came out did such a great job I was so amazed how will they did considering the conditions they were working with in such Heat I feel so bad for them but overall I couldn't have asked for a better crew
everyone is so nice weather its the office or worker
Installation was awesome! Highly recommended!!
Great customer service!
Super tune up performed this evening. Two year old Trane heat pump with air handler. All electrical connections are tight with no corrosion. X13 blower motor is acceptable. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed. Customer has signed up for the military appreciation membership.
Electrical to HVAC He's concerned with his compressor, says it keeps coming on without performing any function so no air is blowing and then shuts off again
2023 American Standard Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Blower motor and wheel were Evaporator coil was acceptable Condensate pan has slight biological growth build up Supply plenum was acceptable 2023 American Standard Straight Cool Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Recommended UV system to keep Airhandler and air quality clean and compressor saver as compressor is over LRA limit. Signed up for HBPPLAN
2021 Lennox Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Blower motor and wheel were acceptable Evaporator coil was acceptable Heatstrips were functional and within manufacture range 2021 Lennox Heatpump Checked and tightened all electrical connections Dual Run cap is right at manufacture tolerance Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed top of the unit Recommended HBPPLAN, UV 300 or 200, dual run cap and compressor saver
Upon arrival system was flat. Added nitrogen to the system And leak detector picked up on trace amounts of 410 in the same location of the previous company. Gave pricing on parts and customer stated he's going to wait and weigh out options
2022 Amana Airhandler Checked and tightened all electrical connections Drain has slight build up but is still draining Changed customer provided filter Blower motor and wheel were acceptable Evaporator coil was acceptable UV system is functional UV lamp is out and needs replacement 2022 Amana Heatpump Checked and tightened all electrical connections Dual Run cap was within manufacture range Primary electrical unit was acceptable Compressor saver is functional Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from inside out Waxed the top of the unit Recommended lamp replacement or UV system upgrade Replaced UV lamp today
.
Level 5 24k whole home automatic generator $21,000
Performed cooling tuneup on a gas furnace checked both indoor and outdoor units changed customer supplied filter. Everything is working within manufacture spec on the indoor unit washed the outdoor coil off checked all electronics and pressures and everything is also within a manufacture spec gave some recommendations but system is working properly.
Replaced blower and started system. Left with system in cool mode
Upon arrival tech found that the ECM blower motor wasn't working properly system need a new ECM motor system is a down flow technician is pausing job till homeowner gets approved for financing
7/28/25 Pausing job home warranty company getting there to visit with homeowner
Performed Tune up on upstairs only per customer request 2003 Rheem Airhandler and condenser Found multiple issues like blower and coil having heavy biological growth and dust build up Evaporator coil has heavy rust build up as well P trap on primary drain is sweating and dripping onto ceiling Dual run cap is weak and out of manufacture range Primary electrical unit has heavy pitting and carbon build up Condenser coil has two spots that are corroded Washed condenser coils from inside out Cleared debris from the bottom of the unit Recommended comfort advisor due to the many issues and age of the system, recommended for upstairs and master bedroom system Comfort Advisor Visit setup today for 12-3 confirmed by office
Performed Tune up on upstairs and downstairs systems 2004 Trane upstairs and downstairs Gas Furnaces Checked and tightened all electrical connections Filters were acceptable Drains were clear and draining at this time Blower motors and wheels have heavy dust build up Evaporator coils have heavy dust build up Evaporator coils has heavy corrosion 2004 Trane upstairs and downstairs Straight Cool condensers Checked and tightened all electrical connections Dual run cap for upstairs was within manufacture range Compressor cap for downstairs was within manufacture range Fan cap for downstairs is weak and below manufacture tolerance Upstairs primary electrical unit has heavy pitting and carbon build up Bothell compressor savers are non functional Refrigerant levels were showing slightly low Upstairs compressor was tripped on thermal overload load and would not start until washed Condenser coils were heavily compacted with dust and dirt Washed condenser coils from inside out
Replaced attic GFCI it was tripping in attic.Most likely just nuisance tripping. Everything working good. Offered membership. Customer is interested in getting AC tune up done biannually but not membership.
Provided estimate for customer on our halo water conditioner filtration system. Customer system now is only 5 years old and in good condition. He is going to speak to his wife about our system cause he liked the idea of no salt.
Upon arrival tech found that the system to be working properly tech found no corrosion on electrical connections all wires are tight. Tech didn't find any biological growth tech did find the the inrush amp draw was high tech installed a compressor saver. The inrush has gone down tech showed the homeowner. Tech has a plumber coming out today for water softener
Upon arrival tech found that the drain switch was tripped tech cleared drain and made sure drain was unclogged. Tech cleaning up water system is working at this time
Airhandler Checked and tightened all electrical connections Filter was acceptable Drain was clear and draining Blower motor and wheel are heavily compacted with dust and dirt build up Evaporator coil has slight dust and dirt build up Blower sheet metal door was not attached allowing air to bypass the coil causing the coil to freeze. Comfort Maker straight cool Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were showing with range after eliminating coil bypass issue Fan blades and motor were acceptable Condenser coils needs to be washed but unable to fully complete tune up do to heavy grass and thorns growth. Recommended customer mow and weed eat around unit before washing as well
Failed dual run cap, replaced under warranty. Reset system and left with system cooling
Upon arrival customer stated that multiple things in trailer weren't working. Inspected breaker feeding trailer and noticed breaker has been arcing behind and caused failure on a phase. Unrelated to work preformed last firday. However going in panel could have ,oved breaker enough to being existing issue to light. Customer had a 60 a square d qo breaker that was removed when I did the job. I replaced breaker for him and all is working. Charged service fee. Not a call back
Installed 30a 240v dryer plug fed from existing large feeders. Replaced 125a breaker with 30a breaker. Customer has 3 wire cord here that will be installed by appliance tech. Customer is having dryer serviced. Was unable to test unit. But tested voltage with meter and all reads correctly. Customer paid cash. PIF.
2023 Revolv Airhandler Checked and tightened all electrical connections Recommended changing filter soon Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable 2015 straight cool condenser Checked and tightened all electrical connections Dual run capacitor is weak Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser were heavily compacted with dust and dirt Cleared debris from bottom of the unit Washed condenser coils from inside out Waxed top of the unit Recommended Comfort Advisor for possible duct replacement, Auxiliary motor starter, compressor saver and UV system
2019 Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Blower motor and wheel have dust and hair build up Evaporator coil was acceptable 2019 Bryant Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from bottom of the unit Washed condenser coils from inside out Waxed top of the unit Recommended blower cleaning, Anti Microbial Pan Treatment and Compressor Saver