Simple Answer: We always answer the phone, and come when you call to fix what needs fixed — and we stand behind our word and our work.
Plus you can count on getting a Certified AC Genius, Plumbing Genius, or Electrical Genius. Which means we don’t use “salesmen in disguise” or “selling techs,” like other home service companies. Instead we have our own training center to ensure you always get the honest expertise required to repair your problem right, right then and there.
Very professional, explained what he was doing and was very courteous.
On a scale of 1-10, with 10 being best,,,,I may give Colby an 11. He was extremely knowledgeable, honest, down to earth, and wasnt the least bit coming out of the gates trying to sell something. Top Notch.
Blake was very honest and detailed. Very satisfied.
This is the second time Derek has been to my home representing Comfort Experts. Each time he's been courteous, efficient and professional. He did his job checking out my heating unit cleaning my outside a/c unit and patiently answered all of my questions. I feel that Comfort Experts does an excellent job of making their customers feel valued.
Performed super tune up requirements Washed condensor and tightened connections Filters were recently replaced Delta 21 Performed evaluation on – loose noise from blower start up Installed Soft start kit LRA from 120amps to 20 amps Installed primary electrical control unit Holding for parts – indoor blower motor 240v 1/3HP – 1050 RPM System left on cool at exit
System for the living room and bedroom flute pipe was popped offI turn off the gas until someone can come out and fix it and there no trap or vent for the other systems drain all safeties and amperage‘s are within range system had a little bit of biological growth in the supply plenum
I completed a level 1 duct cleaning here cleaned out all the vents and ducts
Was here to replace a motor so I took out the temporary motor put in the new X 13 motor system now heating and reinstalled our great value light up light the bulb is a lsk-24v-14 he would like us to come out Wednesday to do a duct cleaning
Arrived at customers house for heat tune up All components working to manufacture spec Recommended duct clean lvl 1 for dust build up Recommended anti microbial mist and pan strip for biogrowth Recommended membership conversion All declined as of this time
System was hitting high pressure check the refrigerant, when in cooling was within the range. blower motor was working intermittently causing system not to heat so I put in a temp motor till we can get the new one in. Will need to come back as soon as possible
I was here for a super tune up the system has good delta .Filter was just changed and I poured white vinegar down the drain lines.blower was dirty and some biological growth was growing in the system heatstrips were in tolerance. Capacitor was in tolerance ,and all amperage were in range. refrigerant was within range and the condenser was cleaned
System is at factory specs filter was dirty condenser was cleaned
Came out for an evaluation found a blown fuse in the indoor unit due to a fried UV system remove the UV system and replaced the fuse everything is running as it should
07/08/24 TS- waterheater was not working when I arrived. And did a quick dionostic on the waterheater to see the issue. Because of the age and issue with flame valve, I suggest replacing the unit. Customer agreed upon replacing unit tomorrow once the purchase a new customer supplied waterheater.. Schedule tomorrow 07/08/24 Tuesday for installing new unit
Replaced a warranty hard start for a 4 ton and a dual run 45/5 cap 4 ton hard start and 45/5 dual run cap
Arrived fit CTU filter fine Drains clear System functioning fine with no issues Recommend electrostatic/ polarized filter and UV upgrade with a full system clean Panel surge protection recommended as well
Tech arrived at rec work. The AprilAire filter upgrade kit and filter was installed today. The IAQ 200 UVC System and Air Cleaner was installed, tested and functional. A treatment strip was added to help keep the drain system clean. The system was functioning upon departure.
Tech arrived at a warranty tuneup. Upon inspection, the capacitor was within specs. The contactor was in working condition. The Delta was within range. The filter was dirty and allowed unfiltered air to enter the system. The blower area and ductwork was dirty. The drain was clear and bleach was poured. The customer was informed of recommendations today. She decided to move forward with adding an UVC System and Air Cleaner and an AprilAire filter upgrade kit to the system. The customer would like for this to be performed next week, any day except for Wednesday. The system was functioning upon departure.
03/15/24 Tyler S- waterheater bottom has blown out and gas smell is from the tank not being fully closed. Shows s8gns of rot around flame casing. New waterheater would need a new shut off valve, expansion tank, and gas drip line 50gal natural gas waterheater
2013 5 ton American Standard 410a HP. Drain line clear. Filter replaced. Blower wheel/ motor inspected. Evaporator coil inspected. Amps and volts inspected. Electrical tightned. UV bulb replaced. Condenser fan 10mfd capacitor replaced. Refrigerant levels acceptable. System is in healthy condition.