Simple Answer: We always answer the phone, and come when you call to fix what needs fixed — and we stand behind our word and our work.
Plus you can count on getting a Certified AC Genius, Plumbing Genius, or Electrical Genius. Which means we don’t use “salesmen in disguise” or “selling techs,” like other home service companies. Instead we have our own training center to ensure you always get the honest expertise required to repair your problem right, right then and there.
Daniel S. was prompt, explained what needed to be done and took care of it. He’s polite and wanted to make sure it was done and ready for the the seasons!
Daniel was very helpful, explained things along the way and gave pointers to keep our system running smoothly in the future!
6 hour wait. Promised first call at 10am. Completed minor repair at 4:15pm.
Jordan did an excellent job. Very professional and courteous
Very good job.
Great job
Performed cooling tune up Washed condensor and tightened connections Delta 17 – refrigerant is good All cooling components are in tolerance Replaced filter Reccomended home and budget plan Reccomended Drain saftey Reccomended soft start or compressor saver Reccomended capacitor Reccomended primary electrical control unit Reccomended 26×54 1/2 attic tent Homeowner will contact home warranty for system repairs/concerns System left on cool at exit
Arrived onsite customer was concerned for water heater cause shower were not getting hot in master bathroom. Inspected everything and the water heater is putting out hot water to all the fixtures in home except the master bathroom. Recommend changing out shower cartridge the homeowner said he knows how to change the cartridges out will do it himself.
I changed one of the systems filters and both blowers were a little dirty one drain pan had rust both coils have corroded a little bit.the duct are very dirty need a duct cleaning inducer motor amperage within tolerance condenser outside. One of them had a capacitor out of tolerance recommend changing it out. All amperage is within range and refrigerant within tolerance customer want a plumber to come out on Monday the 27th any time after 4 to check out why there are Little Rock’s coming clogging the faucets and not getting as hot
Arrived for evaluation System down at arrival Compressor not running at start Found capacitor failed to run Replaced capacitor – system running Reccomended home and budget plan System left on cool at exit
Zoom board defective Delta at 20 refrigerant looks good capacitor at a tolerance does not want to change out could not clean condenser cuz a short hose
Zoom board defective Delta at 20 refrigerant looks good capacitor at a tolerance does not want to change out could not clean condenser cuz a short hose
For the evaluation I showed up to the customer's home for a no cool. I took a thermal image of the supply where it was blowing out at 76°. The customer stated his neighbor had added some are 410A yesterday, roughly 2 lb. At the condenser I gauged up and I had a 63⁰ SH, 0⁰ SC indicating the system is extremely low on refrigerant. I opened the coil panel and instantly saw vapor leaking out and found the leak on one of the capillary tubes. The customer has a substantial leak in the evaporator coil. I talked to customer about the cost of replacement and he would like to talk to a CA Monday 5 August.
Gave customer estimate on adding a sink light above sink. 2 different options. One to add to existing lighting in kitchen. A second one to install new dimmer and put light on separate switch. Interested in membership but not ready to bite.
Daniel S. completed annual hvac tuneup.
Arrived for two system STU All components were working and in tolerance besides the upstairs cap Recommend compressor savers, dual cap and duct cleaning Customer wants to wait
Arrived onsite was able to find the prv valve in the flower bed and adjusted the valve so that the pressure would be coming out better. On previous water pressure was 40 psi. I adjusted prv to 75 psi
Arrived for Eval Customer stated that this system has had drain problems before Recommend drain clear and pan strip Customer okayed Drained drain line and installed pan strip System was running before I left
Performed water pressure test on home and the pressure coming into home is 45 psi. Also cleaned out the screen on cold Water inlet for water heater had a lot of debris in it.
Arrived for Eval System runs but the primary drain line was clogged. Recommend Drain line disassembled and clear, drain switch, IAQ 200 and membership Customer okayed all rec Drained drain line and installed drained switch Installed IAQ 200 System running before I left.
Yucca guy thh G had him try uv gf
Annual heat and air conditioning tune ups completed.
Tech arrived at a 2 system tuneup. Upon inspection, the capacitors were within specs. The condenser coils were hosed off to assist with air flow across the coils. The master condenser fan motor was pullibg high amperage. The filters were replaced. The master system refrigerant and Delta was low. The drain was clear and bleach was poured. The blower areas were dirty. The indoor coils were rusted. The customer was informed of recommendations today. They will inform their warranty company.
1/25/25 Will get new waterheater tomorrow and return
12/23/23 Tyler S- needs to replace pull down kitchen faucet supply line. They are special supply lines that isn't sold at box stores. No name brand on faucet to help track parts. More then likely will need to replace faucet